Veuillez ajouter au panier pour la conserver ou quitter la configuration
Fils et câbles chauffants

Fil résistant en boudin en alliage nickel-chrome
NIC60-NIC80
Coiled 80% Nickel 20% chromium or 60% nickel 16% chromium resistance heating wire from 18 to 30 AWG, lengths up to 1000 ft, temperature up to 2100°F and corrosion resistant.
Voir les spécifications complètes
1400°F Max 80 Nickel 20 Chromium Resistance Heating Ribbon
NCRR-Series
NCRR-Series 80% Nickel 20% chromium resistance ribbon heating wire available in 18 to 30 AWG, lengths up to 1000 ft and maximum temperature of 1400°F.
Voir les spécifications complètes
Fil résistant chauffant en alliage 80% nickel/ 20% chrome
NI80
NI80 80% Nickel 20% chromium resistance heating wire available in 18 to 30 AWG, lengths up to 1000 ft, maximum temperature of 2100°F and corrosion resistant.
Voir les spécifications complètes
Self-Regulating Rapid-Trace Heating Cable/Medium Temperature
SRME-HEATCABLE
Self-regulating heating cable 150°C max, moisture and chemical resistant, 5 or 10 W/ft power density options, used for temperature maintenance and freeze protection.
Voir les spécifications complètes
Fil résistant chauffant en alliage 60% nickel/ 16% chrome
NI60
NI60 60% Nickel 16% chromium resistance heating wire available in 18 to 30 AWG, lengths up to 1000 ft, maximum temperature of 1850°F and corrosion resistant.
Voir les spécifications complètes
204°C Max Constant Wattage Heating Cable 120-480 Vac
FE-HEATER
Constant wattage heating cable 204°C max, moisture and chemical resistant, 3, 5, 8 or 12 W/ft power density options, used for pipe tracing and freeze protection.
Voir les spécifications complètes
Self-Regulating Heating Cable/Low Temperature
SRL-HEATCABLE
Self-regulating heating cable 85°C max, moisture and chemical resistant, 5 or 10 W/ft power density options, used for temperature maintenance and freeze protection.
Voir les spécifications complètes
200°C Max Constant Wattage Heating Cable 120-480 Vac
CWM-HEATCABLE
Constant Wattage Heating Cable FEP overcoat and tinned copper overbraid insulation, 4, 8, 10 or 12 W/ft power density options, used for pipe tracing and freeze protection.
Voir les spécifications complètes
260°C Max Constant Wattage Heating Cable 120-480 Vac
KE-HEATER
Constant wattage heating cable 260°C max, moisture and chemical resistant, 4, 8, or 12 W/ft power density options, used for pipe tracing and freeze protection.
Voir les spécifications complètes
Heat Trace Power Connection, End Seal, and Splice Kits
HT-KIT
Heat trace kits including single or multiple connection power connection kits, end seal kits with or without indication lights and splice kits and rated for hazardous areas.
Voir les spécifications complètes
Heat Trace Essentials Tape, Clamps, and Caution Labels
HT-ESSENTIAL
Heat trace essentials including aluminum and fiberglass tape, clamps for different pipe size and caution labels.
Voir les spécifications complètesFils et câbles chauffants
