Appelez-nous au 1-888-826-6342
Retour au sommet
Charger plus d‘articles de cette famille (9) ...
Étalons à bloc sec et bains
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Ajouté à votre panier
Ambient + 5°C to 450°C temperature range dry block has ±0.4°C high accuracy with well to well radial uniformity to 0.020°C.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
Ambient -5°C (-9°F) to 450°C (850°F)
|
±0.4°C (50 to 400°C) ±0.7°F (122 to 752°F) ±0.7°C (400 to 450°C) ±1.3°F (752 to 850°F)
|
±0.050°C (50 to 400°C) ±0.090°F (122 to 752°F)
|
120V
|
Interchangeable multi diameter well
|
None
|
Compact & Portable
|
|
Ambient -5°C (-9°F) to 450°C (850°F)
|
±0.4°C (50 to 400°C) ±0.7°F (122 to 752°F) ±0.7°C (400 to 450°C) ±1.3°F (752 to 850°F)
|
±0.050°C (50 to 400°C) ±0.090°F (122 to 752°F)
|
230V
|
Interchangeable multi diameter well
|
None
|
Compact & Portable
|
The TCL series of Dry Block and Micro Bath calibrators feature Extremely High Accuracy and Stability with a Certificate of Calibration Included with every unit.
Numéro de produit | Process Temperature Range | Stability | Supply Voltage |
---|---|---|---|
|
-35°C (-31°F) to 165°C (329°F)
|
±0.05°C
|
100/240 Vac
|
|
-21°C (70°F) to 255°C (491°F)
|
±0.05°C
|
100/240 Vac
|
Dry block with temperature range from ambient +5°C to 400°C has ±0.6°C display accuracy and 0.15°C stability after 15 minutes.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
Ambient +5°C (9°F) to 400°C (752°F)
|
±0.6°C (1.1°F)
|
±0.15°C (0.27°F)
|
120 Vac
|
None
|
None
|
Portable
|
|
Ambient +5°C (9°F) to 400°C (752°F)
|
±0.6°C (1.1°F)
|
±0.15°C (0.27°F)
|
240 Vac
|
None
|
None
|
Portable
|
Ambient +11 to 260°C temperature range dry block with ±1.5°C accuracy and ±0.15°C stability. 4 different well styles available. Click here to see.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
Ambient + 11°C (20°F) to 260°C (500°F)
|
±1.5°C (±2.75°F)
|
±0.15°C (±0.3°F)
|
115 Vac
|
Well Style A
|
None
|
Compact & Portable
|
|
Ambient + 11°C (20°F) to 260°C (500°F)
|
±1.5°C (±2.75°F)
|
±0.15°C (±0.3°F)
|
115 Vac
|
Well Style B
|
None
|
Compact & Portable
|
|
Ambient + 11°C (20°F) to 260°C (500°F)
|
±1.5°C (±2.75°F)
|
±0.15°C (±0.3°F)
|
115 Vac
|
Well Style C
|
None
|
Compact & Portable
|
|
Ambient + 11°C (20°F) to 260°C (500°F)
|
±1.5°C (±2.75°F)
|
±0.15°C (±0.3°F)
|
115 Vac
|
Well Style D
|
None
|
Compact & Portable
|
|
Ambient + 11°C (20°F) to 260°C (500°F)
|
±1.5°C (±2.75°F)
|
±0.15°C (±0.3°F)
|
115 Vac
|
Well Style A
|
RS232
|
Compact & Portable
|
-5 to 125°C temperature range dry block provides ±0.8°C accuracy with fast heating time. RS232 output and free SW. click here to see more features.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
-5°C (23°F) to 125°C (257°F)
|
±0.8°C (±1.5°F)
|
±0.25°C (±0.45°F)
|
115 Vac
|
Standard Wells
|
RS232
|
Portable
|
|
-5°C (23°F) to 125°C (257°F)
|
±0.8°C (±1.5°F)
|
±0.25°C (±0.45°F)
|
230 Vac
|
Standard Wells
|
RS232
|
Portable
|
|
-5°C (23°F) to 125°C (257°F)
|
±0.8°C (±1.5°F)
|
±0.25°C (±0.45°F)
|
230 Vac
|
Metric Wells
|
RS232
|
Portable
|
Fluidized baths are small by design and are meant for laboratories and instrument shops. Two Temperature Ranges: 122 to 662°F (50 to 350°C) 122 to 1112°F (50 to 600°C).
Numéro de produit | Process Temperature Range | Stability | Supply Voltage |
---|---|---|---|
|
50°C (122°F) to 600°C (1112°F)
|
±1.0°C
|
117 Vac
|
Surface plate calibrator with temperature range from 35°C to 450°C has accuracy to ± 2.0°C and 124 mm target plate diameter.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
35°C (95°F) to 450°C (842°F)
|
± 2.0°C (3.6°F)
|
± 1.7°C (3.0°F)
|
120 Vac
|
None
|
None
|
Portable
|
|
35°C (95°F) to 450°C (842°F)
|
± 2.0°C (3.6°F)
|
± 1.7°C (3.0°F)
|
240 Vac
|
None
|
None
|
Portable
|
Hot point dry block with ambient +22°C to 482°C temperature range provides accuracy to 0.9°C. Built-In 5 port well design.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
Ambient +22°C (40°F) to 482°C (900°F)
|
±0.9°C (1.5°F)
|
±0.2°C (0.3°F)
|
110 Vac
|
Single Well
|
None
|
Portable
|
|
Ambient +22°C (40°F) to 482°C (900°F)
|
±0.9°C (1.5°F)
|
±0.2°C (0.3°F)
|
220 Vac
|
Single Well
|
None
|
Portable
|
Hot point dry block has temperature range from ambient +22°C to 482°C with accuracy to ±0.8°C, stability to ±0.2°C and RS-232 output.
Numéro de produit | Process Temperature Range | Accuracy Value | Stability | Supply Voltage | Style | Communications Protocol | Additional Features |
---|---|---|---|---|---|---|---|
|
Ambient +22°C (40°F) to 482°C (900°F)
|
±0.9°C (1.5°F)
|
±0.2°C (0.3°F)
|
115 Vac
|
Single Well
|
RS232
|
Portable
|
|
Ambient +22°C (40°F) to 482°C (900°F)
|
±0.9°C (1.5°F)
|
±0.2°C (0.3°F)
|
230 Vac
|
Single Well
|
RS232
|
Portable
|
Étalons à bloc sec et bains
Dry block and bath calibrators are instruments used in many industrial, commercial, and laborat...
[+]