Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

Simulateur/thermomètre thermocouple portatif avec USB{USB}{RS232}{WINXP}

Calibrator/Thermometer
Warranty
  • RoHS Icon

C$582.52

Article# CL3515R

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$582.52
5-9 C$553.39
10-24 C$541.74
25-49 C$518.44
50-99 C$506.79
100+ C$495.14

En stock

Délai de livraison (si pas en stock): 12 semaines
Calibrator/Thermometer CL3515R CL3515R
  • USB et interface RS232 avec logiciel Windows
  • 11 types de thermocouples: K, J, T, E, R, S, N, L, U, B, et C (en °C, °F, ou K), et sortie signal mV
  • 2 Chaînes pour mesures de température thermocouple (T1 et T2) avec ajustement Offset
  • Sélecteur rotatif ergonomique permet l'opération avec une main

CL3515R Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Type of Thermocouple Signals
Type of RTD signal
Type of Thermistor Signal
Accuracy Value
Communications Protocol
Battery Run Time
Additional Features


Description

Le CL3515R est un calibrateur/thermomètre avec un affichage rétroéclairé à 4 digits. Il a été conçu pour mesurer et simuler une large plage de types de thermocouples: K/J/T/E/R/S/N/L/U/B/C. Il y a aussi une plage de tension de sortie de -25mV à + 75mV.
Le thermomètre présente une double entrée thermocouple et un offset thermocouple ajustable.

CARACTERISTIQUES
Thermocouple (Résolution) plage de mesure*:
    K: (0,1°) -200 à 1372°C
    J: (0,1°) -210 à 1200°C
    T: (0,1°) -250 à 400°C
    E: (0,1°) -250 à 1000°C
    R: (1°) 0 à 1767°C
    S: (1°) 0 à 1767°C
    N: (0,1°) -200 à 1300°C
    L: (0,1°) -200 à 900°C
    U: (0,1°) -200 à 600°C
    B: (1°) 600 à 1820°C
    C: (1°) 0 à 2316°C
* Selon la température standard ITS-90.
Précision:
    Thermocouple types K/J/T/E/L/U:
    ±(0,05% lec + 0,5°C) -50 à 1372°C
    ±(0,05% lec + 1,0°C) -50 à -250°C
    Thermocouple type N:
    ±(0,05% lec + 1,0°C) -50 à 0°C
    ±(0,05% lec + 0,5°C) 0 à 1300°C
    Thermocouple types R/S/B/C:
    ±(0,05% lec + 2°C) 0 à 1767°C
Plage de simulation de thermocouple:
    Résolution: 0,1° (1° pour R/S/B/C)
    Précision*: ±(0,3°C + 10 µV)
* Précision est spécifiée pour les températures de fonctionnement de 18 à 28°C pedant 1 an, ne comprend pas des erreurs du thermocouple.
Plage mV : -25 à 75 mV
    Résolution: 10 µV
    Précision: ±0,025% + 1 digit
Coefficient de température: 0,1 fois la spécification de précision par °C de 0 à 18°C et 28 à 50°C 
Affichage: 4 digits, rétroéclairé avec lecture maxi de 19999
Connecteur entrée: prise thermocouple miniature (SMP) Alimentation: batterie 9V (comprise)
Autonomie batterie: 17,5 heures, nominale avec indicateur batterie faible
Dimensions: H 192 x L 91 x D 52,5 mm
Poids: 320 g
Plages de fonctionnement ambiantes environnementales: 0 à 50°C, <80% HR
Plages de stockage: -20 à 60°C, <70% HR
loading all models
loading all reviews
Rated 2 out of 5 by from OK Quality 2 channel calibrated unit We bought this because it is calibrated. Seems susceptible to EMI. The HVAC system combined with other adjacent CE compliant test equipment cause this to fail the self test. Other thermometers and test equipment do not fail under the same conditions. It is good that it reports the errors, but it would be nice if it was more robust. Good tech support to identify EMI as the cause.
Date published: 2017-06-27
Rated 1 out of 5 by from Does not work with Windows 10 This product will not work with Windows 10 and no relief in sight...
Date published: 2018-12-06
Rated 4 out of 5 by from Meets my needs I still have a lot to learn about all the capabilities of this equipment, but it works for my calibration needs. I would like to see more documentation on the capabilities and how to use them. What I have seen thus far is a bit lacking for me. I haven't had the opportunity to play with it outside of performing my calibrations. However, it is great for my calibration needs
Date published: 2018-10-25
Rated 5 out of 5 by from Impressive Accuracy I have purchased 3 of these over the past couple of years for training customers on properly performing SAT's and they work great. They are every bi as accurate as $2,000 calibrators we have used in the past and they handle a wide range of thermocouples.
Date published: 2017-10-10
Rated 1 out of 5 by from Rarely in specification Always having to adjust and issuing out of tolerances. Get what you pay for, buy a Fluke.
Date published: 2019-10-08
Rated 3 out of 5 by from Works, but not great It does produce a TC signal that is accurate and adjustable. There are 2 outputs, but they do not seem to be independent, they both put out the same signal. The temperature logging is kind of confusing and it is easy to get stuck in an unknown state. It also beeps very loudly each time you press a button.
Date published: 2024-03-21
Rated 5 out of 5 by from Staff Mechanical Engineer Simple and straightforward usage with multiple thermocouple type input accepted.
Date published: 2023-02-27
Rated 1 out of 5 by from Poor first impression, no OEM support available Of 3 new units we received, 2 were found to be out of tolerance in various ranges, the 3rd one very close to 100% tol. Can't get them adjusted either, since within Europe Omega no longer offers service for this model.
Date published: 2022-11-24
  • y_2024, m_4, d_26, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_8
  • loc_en_CA, sid_CL3515R, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
loading all QA

How do you change take the unit out of REC mode?

Asked by: TRoy962
Hi TRoy962, Thank you for the inquiry. To exit REC mode press and hold Min/Max button for 2 seconds. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-04-19

What is the tolerance of the NIST-Traceable Calibration Certificate with 7 Data Points (Included)? I need to stay within +/- 3 degrees Fahrenheit.

Asked by: jaytee88
Hi jaytee88 Thank you for the inquiry. Certificate will show the values meet specifications in the manual pages 3-4. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-12-03
  • y_2024, m_4, d_27, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_10
  • loc_en_CA, sid_CL3515R, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 37ms
  • QUESTIONS, PRODUCT
Retractable Sensor Cables for Thermocouples, RTDs and Thermistors
C$47.35
3 In Stock
Accessories
J cable (retractable with 2 SMP-M)
C$49.09
3 In Stock
Surface probe, up to 815°C (1500°F)
C$330.76
0 In Stock
K cable (spare)(retractable with 2 SMP-M)
C$45.50
12 In Stock
E cable (retractable with 2 SMP-M)
C$49.09
3 In Stock
Optional thermocouple probe
C$82.98
296 In Stock
fr-CA
fr
Enregistrer la configuration