- Fast Access Menu—Front Key Access to Modify the Alarm Setpoints and Max/Min Memory
- External Control Function—Contact at Multifunctional Terminal 5 (Second Scaling, Decimal Point Change, ‘Hold’ the Reading or Activate the Max/Min Memory)
- Automatic, Power Saving Eco Mode
- Alarms 1 or 2, Independent, Configurable as Max/Min, with Setpoint and Hysteresis
DP20 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Alarm Output
Retransmission Output
Communications
Measurement Type
Input Type
Number of Inputs
Form Factor
Display Type
Max Sampling Rate
Supply Voltage Type
OMEGA’s DP20 series new universal panel meter delivers high performance in a 1/8 DIN size for panel mount, and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (mA & Vdc), resistance, and true RMS voltage and current. By configuration, it will work as an AC and DC voltmeter (up to 600 V) and AC and DC ammeter (up to 5 A) offering application flexibility for process control and industrial requirements. A single universal power supply allows this unit to be suited for global use.
Introduce Omega DP20 Series The optional relays, analog output, and Modbus® RTU serial communications provide customization, control and communication capability. Additional features of the economical DP20 panel meter include scaling, NEMA 4 (IP65) protection, and programmable decimal points.
Specifications
Digits: 4
Reading: 9999 / -1999
Decimal Point: Configurable
LED Color: Red
Digit Height: 14 mm (0.55")
Accepted Signal Ranges: See tables on pdf page 4 for more information
AC Voltages and AC Currents: 600 Vac, 200 Vac, 20 Vac, 2 Vac, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure)
DC Voltages and DC Currents: ±600 Vdc, ±200 Vdc, ±20 Vdc, ±2 Vdc, ±200 mVdc, ±60 mVdc, ±5 Adc, ±20 mAdc
Thermocouples: K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
Probes:
Resistive ‘Pt’ Probes: Pt100 with 2 and 3 wires, Pt500, Pt1000
Resistive ‘Ni’ Probes: Ni100, Ni200, Ni1000
Resistive NTC Probes: See table at page 4
Resistive PTC Probes: Families KTY-121, KTY-210 and KTY-220
Process: 4/20 mA, 0/10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
Resistances: Ranges 0/5 K and 0/50 K
Potentiometers: With nominal values from 500 R up to 20 K
Thermal Drift Offset+Span: 150 ppm/ºC
How to Open/Close the Omega DP20 Housing Readings: 3 readings/ second
Refresh: 3 readings/ second
Response Time: <300 mSec. (0 % to 99 % of signal)
Power ‘U’: 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
Output and Control Options:
1 or 2 Relays: 1 Analog output 4/20 mA isolated
1 Modbus RTU isolated serial output
Protection: NEMA 4 (IP65)
Consumption (Normal Mode): <1.0 W (meter only) <2.5 W (meter with options)
Consumption (‘Eco’ Mode): <0.3 W (meter only) <1.5 W (meter with options)
Connections: Plug-in screw terminals
Weight: <150 g (5.3 oz)
Operation Temperature: 0 to 50ºC (32 to 122ºF)
Specifications
Digits: 4
Reading: 9999 / -1999
Decimal Point: Configurable
LED Color: Red
Digit Height: 14 mm (0.55")
Accepted Signal Ranges: See tables on pdf page 4 for more information
AC Voltages and AC Currents: 600 Vac, 200 Vac, 20 Vac, 2 Vac, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure)
DC Voltages and DC Currents: ±600 Vdc, ±200 Vdc, ±20 Vdc, ±2 Vdc, ±200 mVdc, ±60 mVdc, ±5 Adc, ±20 mAdc
Thermocouples: K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
Probes:
Resistive ‘Pt’ Probes: Pt100 with 2 and 3 wires, Pt500, Pt1000
Resistive ‘Ni’ Probes: Ni100, Ni200, Ni1000
Resistive NTC Probes: See table at page 4
Resistive PTC Probes: Families KTY-121, KTY-210 and KTY-220
Process: 4/20 mA, 0/10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
Resistances: Ranges 0/5 K and 0/50 K
Potentiometers: With nominal values from 500 R up to 20 K
Thermal Drift Offset+Span: 150 ppm/ºC
Refresh: 3 readings/ second
Response Time: <300 mSec. (0 % to 99 % of signal)
Power ‘U’: 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
Output and Control Options:
1 or 2 Relays: 1 Analog output 4/20 mA isolated
1 Modbus RTU isolated serial output
Protection: NEMA 4 (IP65)
Consumption (Normal Mode): <1.0 W (meter only) <2.5 W (meter with options)
Consumption (‘Eco’ Mode): <0.3 W (meter only) <1.5 W (meter with options)
Connections: Plug-in screw terminals
Weight: <150 g (5.3 oz)
Operation Temperature: 0 to 50ºC (32 to 122ºF)
Rated 5 out of
5
by
Nathan DCS from
Process temp
It was very pleased with this controller it was easy to use program and set up.
Date published: 2022-08-11
Rated 5 out of
5
by
Electricman from
Versatile meter
Very versatile meter. Multi-input covers just about any need you may have. Easy programming also.
Date published: 2022-08-01
Rated 2 out of
5
by
Knudsen from
A step backwards in quality.
Much lower quality than the now discontinued displays we would get from Omega. The bezel feels like it's going to break when (you must) take it off. Has to be exactly right, in order to put back on. It may have some more features, but the enclosure is really poorly constructed. I feel for the person that would need to deal with this on-site in a dark, dusty basement. The unit is setup with a hand-full of PCB jumpers. I though that we had evolved beyond that in the 90's. I have not tested the dubious-looking panel clamps.
Date published: 2020-12-16
- RoHS 2015/863 - Voir le certificat
- Approuvé CE
- Listé UL cULus
Can a DP-25 meter be upgraded with an analog output card after installation?
Thank you for your inquiry. Unfortunately the DP20 meter must be ordered with an analog output. No field-installation.
Date published: 2022-10-06
Does the DP20-S1 come with the female screw terminals included?
This unit has a terminal block with jaw-lock screw terminals.
Date published: 2020-01-28