Module USB d&#39acquisition de données d'entrée thermocouple/tension 8/16 canaux

Portable USB thermocouple/voltage input data acquisitionmodule

C$1,285.63

Article# OM-DAQ-USB-2401

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$1,285.63
5-9 C$1,221.35
10-24 C$1,195.64
25-49 C$1,144.21
50-99 C$1,118.50
100+ C$1,092.79

En stock

Délai de livraison (si pas en stock): 6 semaines
Portable USB thermocouple/voltage input data acquisitionmodule OM-DAQ-USB-2401 OM-DAQ-USB-2401
  • 8 entrées analogiques différentielles ou 16 entrées analogiques simples
  • Résolution 24 bits, jusqu'à 1 000 échantillons par seconde
  • Thermocouples de types J, K, T, E, R, S, B, N ou entrée de tension programmable par l'utilisateur
  • 4 capteurs de température de compensation de soudure froide et détection de thermocouples ouvert intégrés
  • Alimentation directe par le port USB ou l'alimentation externe CC
  • Isolation 500 V entre l'entrée et le PC pour des mesures sécurisées et sans parasites
  • Pilote/API .NET gratuit pour Visual Basic, C#, et Visual C++ pour Windows XP, Vista et Windows 7
  • Propose une sortie +12 Vcc pour l'excitation du capteur
  • Livré avec le matériel pour fixation sur un plan de travail, sur un rail DIN ou au mur

OM-DAQ-USB-2401 Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Analog Input Type
Analog Input Class
Number of Analog Inputs
Maximum Sample Rate (per sec)
Analog Input Resolution
Input Range
Power
Interface Protocol
Additional Features


Description

Le modèle OM-DAQ-USB-2401 est un module d'acquisition de données de thermocouple/tension USB 2.0 pleine vitesse (totalement compatible avec les ports USB 1.1 et USB 2.0). Ce module autonome fonctionne grâce à l'alimentation du port USB. Une alimentation externe (proposée en option) peut être utilisée. Toutes les options paramétrables (y compris le type d'entrée du canal individuel et la plage) sont programmables par logiciel.

Le modèle OM-DAQ-USB-2401 intègre des entrées de tension programmables par l'utilisateur couvrant une plage de ±30 mV à ±10 V, à pleine échelle. Le conditionnement compact et modulaire garantit la simplicité d'emploi dans une grande variété d'applications. Les unités peuvent être montées sur un rail DIN ou au mur à l'aide du matériel inclus, qui permet également une utilisation facile sur plan de travail. Tous les canaux d'entrée analogique peuvent être mesurés en séquence à une vitesse approximative de 1 ms par canal. Au total, il est possible de réaliser 1 000 échantillons par seconde répartis sur tous les canaux actifs.

CARACTÉRISTIQUES

Isolation : 500 V depuis le PC
Tension d'excitation externe : 12 Vcc régulée, total max de sortie de courant : 67 mA
Alimentation électrique : alimentation directe depuis le port USB, max 500 mA, ou externe par adaptateur 7,5 à 12 Vcc
Conditions environnementales : 0 à 50 °C, 95 % HR (sans condensation)
Température de fonctionnement : 0 à 50 °C, 0 à 95 % HR sans condensation
Température de stockage : -40 à 85 °C
Poids : 0,23 kg
Dimensions : 107 mm l x 128 mm L x 39 mm H
Plage de tension en entrée : entrée différentielle/simple, programmable par logiciel pour chaque canal
    -10 à 10 V    -500 à 500 mV
    -5 à 5 V     -250 à 250 mV
    -2,5 à 2,5 V    -125 à 125 mV
    -2 à 2 V    -75 à 75 mV
    -1 à 1 V     -30 à 30 mV
Plage d'entrée TC
    Type J :
-18 à 1 200 °C
    Type K : -129 à 1 372 °C
    Type T : -101 à 400 °C
    Type E : -184 à 1 000 °C
    Type R : 204 à 1 768 °C
    Type S : 204 à 1 768 °C
    Type B : 538 à 1 820 °C
    Type N : -129 à 1 300 °C
Entrée TC
Précision du thermocouple :
Typique, en mode très lent, résolution 24 bits
    J = ±1,1 °C
    K = ±1,2 °C
    T = ±1,1 °C
    E = ±1,0 °C
    R = ±2,5 °C
    S = ±2,6 °C
    B = ±3,3 °C
    N = ±1,5 °C
Précision de la compensation de jonction froide : ±1,0 °C
Précision d'entrée analogique :
    Entrée différentielle :
typique, en mode très lent, 0,015 % de la lecture +0,004 % de plage +10 uV (à l'exclusion du bruit)
    Entrée simple : typique, en mode très lent, 0,05 % de la lecture +0,01 % de plage +50 uV (à l'exclusion du bruit)
Type d'équipement USB : USB 2,0 (pleine vitesse)
Compatibilité de l'équipement : USB 1,1, USB 2,0
Alimentation électrique : depuis l'USB ou depuis l'adaptateur universel 9 Vcc (inclus)
Montage sur rail DIN pour les applications en rack : en option
Détection des thermocouples ouverts : activation automatique lorsqu'un canal est paramétré pour un capteur de thermocouple
loading all models
loading all reviews
Rated 2 out of 5 by from Adequate but fragile Basic device does provide USB connection to computer. Software is basic and cumbersome. The device is not robust, recommend unplugging power and USB when not in use.
Date published: 2018-08-06
Rated 2 out of 5 by from OM-DAQ-USB-2400 - Beware when using w/ TCs I purchased four of these units (over time) for use with various thermal experiments involving building assemblies (temperature ranged from 0 to 100F). With 8 differential channels on each unit, this model seemed like a bargain and I've always looked to Omega for easy online shopping and competitive prices. When I started pairing these units together, I noticed pretty significant disagreements between TC readings when calibrating multiple devices at once. This disagreement wasn't resolved with offsets and scaling. I thought my devices needed calibrated, but digging deeper in the specs, I found the combined TC and cold junction compensation error for these units are +/-4F...not good for measurements requiring minimal absolute error, and worse than some of my old Omega handheld loggers. It would have been nice for the specs to provide the total measurement error, with CJC and TC errors together, as other products usually list them. Using this model for analog voltage signal logging has worked well, on the other hand, and the software is simple and easy to use. I'm upgrading to a DAQ-2416 to get better accuracy and I hope I can get more out of this unit even though the $$ per TC channel isn't that different from the USB-2400.
Date published: 2016-12-19
Rated 1 out of 5 by from Did not live up to expectations. The OM-DAQ-USB-2401 was acquired for the purpose of running 5 to 8 load cells. It was recommended specifically for the job, by an Omega support engineer on the phone support line. When received, we found that the label on the top, identifying the ports, was 180 degrees off. We also found that the unit is very restricted with regards to excitation current! It is only capable of feeding 2 load cells, not 8. Very disappointing.
Date published: 2016-11-17
Rated 3 out of 5 by from Calibration issues Calibration Cert not offered but when we tried to calibrate the unit as required for our use, it failed. Had to return the unit for Omega to review because they said it was factory calibrated. If that's the case, then why would a cert not be offered? Frustrating.
Date published: 2022-03-09
Rated 3 out of 5 by from device works but software is limited For my job, I need to connect this device to others in my network, and we only use Linux Systems. Is there some way to config the data acquisition module using standard serial communication? I did make a program with python that can read serial port, but I not have any response. Greetings.
Date published: 2019-07-20
Rated 1 out of 5 by from Not recommended It stopped working after 1-year use, error while setting data scanning rate. Doesn't support USB.
Date published: 2019-05-27
Rated 2 out of 5 by from Caution: Input volt/current spike can damage 2401 The unit is easily damaged if there is a voltage/current spike, this renders the 2401 device useless. This has happened on three of 4 Omega units. Easy to use, but unprotected. Ex: A suspected voltage spike occurred during DAQ, the unit(s) then began showing erratic thermocouple readings. We restarted all devices and found that the Omega 2401 would not "Configure."
Date published: 2018-09-10
  • y_2024, m_5, d_4, h_4
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_CA, sid_OM-DAQ-USB-2401, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
loading all QA

Using the DAQ-USB-2401 unit with analog pressure sensors with 4-20mA output what resistor is required to convert the signal to a voltage, what software settings do you set the DAQ to for voltage input, and how do you get the actual sensor reading?

Asked by: jstan6053
Thank you for your question. We would recommend a 250 ohm resistor OMX-R250 and setting up the Daq device to 5 volt range. https://www.omega.com/en-us/control-and-monitoring-devices/controllers/pid-controllers/p/OMX-R250
Answered by: Kim B
Date published: 2020-09-25

How do I download the free software? I can't get to the FTP site (with Internet Explorer, Chrome, or Edge).

Asked by: Dmtri
Thank you for your question. Please see link to download DaqCentral software: https://software.omega.com/legacy%20web%20software/software-legacy/DAQ-Central.zip
Answered by: Application Engineer PV
Date published: 2022-11-15

Is the DAQ compatible with windows 10? The software installs correctly, but the driver has not.

Asked by: Norman
Thank you for your question. The software is compatible with Windows 10. If you are having issues with installation than please e-mail our Data Acquisition Dept- DAS@OMEGA.COM and they will be able to assist you.
Answered by: Raptor
Date published: 2021-03-10

Which format is the data export to?

Asked by: TanU
Thank you for your question. You can save file as .CSV or Binary.
Answered by: Application Engineer PV
Date published: 2023-05-15
  • y_2024, m_5, d_4, h_4CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_OM-DAQ-USB-2401, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration