Appelez-nous au 1-888-826-6342
Enregistreur graphique circulaire, diagramme Ø 250mm, <br>2 voies entrées universelles
Economical 2-Pen Circular Process Recorder
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$1,992.57 |
5-9 | C$1,892.94 |
10-24 | C$1,853.09 |
25-49 | C$1,773.39 |
50-99 | C$1,733.54 |
100+ | C$1,693.68 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Entrées universelles:
Thermocouple K, T, J, R, S ou B, Pt100 3 fils (-210 à 440°C), 4-20mA, 0-5V - Diagramme de Ø 250mm, rotation en 4 à 168h
- Réglages simples et rapides
- Diagramme maintenu par un aimant, facile à remplacer
- Jusqu'à 48h d'autonomie sur pile de 9V
- Un ou 2 relais configurables en option, avec ou sans retombée
- Boîtier protégé NEMA4/IP65 en option
- Eclairage du diagramme
CT7310-D Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Additional Features
Number of Channels
Measurement Type
Measurement Range
Chart Time
Number of Alarm Relays
Battery Back-up
Description
Le CT7300 est un enregistreur graphique circulaire à 2 voies pouvant recevoir des signaux de thermocouple K, T, J, R, S ou B, de Pt100 3 fils, de boucle de courant 4-20mA ou de tension 0-5V. Cet enregistreur est facile à mettre en oeuvre et peut continuer à fonctionner pendant 48h en cas de coupure d'alimentation grâce à une pile 9V. En option, il est équipé de 1 ou 2 relais et d'une protection NEMA4/IP65 contre les éclaboussures.Pour obtenir les caractéristiques complètes de ces produits, consultez la notice commerciale par le lien en bas de cette page.
- CSA
Hey there any body help me to program CT7130 chart recorder for 4 hours, the manual Says "Chart Speed: Programmable for 4, 8,12, 24, 48, 72,168 hour rotation" and didn;t find any explanation for chart speed control settings
Hi Teknix,
The CT7310 makes use of a set up chart to select sensor, sensor range, chart speed, etc. In the manual page 13 these parameters are simply referred to as categories. Set up charts are included with the recorder purchase.
Best regards
OMEGA
Date published: 2021-12-23
Thanks a lot! My follow up question would then be......could you provide me with the probes that are compatible with these chart recorders?
Best to call in to review you application as we offer hundreds if not thousands of compatible sensors for this product.
Date published: 2020-01-27
Will I be able to use this chart as a stand alone if I buy probes? Or does this one specifically replace a chart recorder on an environmental chamber?
This is a stand alone product that can be used with may different external separately purchased probes. Not specific for any single application only.
Date published: 2020-01-24
Using this chart recorder for simple temperature and humidity monitoring of rooms. Any good probes that you suggest? Please direct me. Thank you.
Hi Tayyyyy,
HX93BV1 has two 0 to 5 V outputs for temperature and humidity.
Best regards
OMEGA
Date published: 2020-02-04
HX93BV1 is able to connect to this chart recorder and read temperature and humidity, correct? Sorry for all the questions, I just want to get the right products for my companies usage before purchasing.
Hi Tayyyy,
I would suggest to consider the CTXL-TRH-W
https://www.omega.com/en-us/control-and-monitoring-devices/recorders/hybrid-paper-recorders/p/CTXL
This recorder includes sensor for temperature and RH.
Chart ranges for the CT7300 series are limited. The temperature and RH outputs of the HX93BV1 have different numerical ranges requiring chart paper with 2 ranges which are not available.
Best regards
OMEGA
Date published: 2020-02-05
Accessories