DIN Rail Conditioners Convert mA or V Inputs to mA or Voltage

The DIN Rail DMD4380 Series converts, amplifies, filters and optically isolates mA or V input signals to process current or voltage outputs. Loop powered w/ 1200V isolation.

DR-I4 Series Signal Conditioner

The LCKD series are Omega's smallest load cells. They are temperature compensated, with ±0.25% linearity and 2mv/V output in capacities from 2.2 lbf to 1,000 lbf.

Transmetteur de Température 2 voies Montage Sur Rail DIN

The TXDIN70 series provide two channel transmitters or isolators with 4-20 or 0-20 mA output. Programmable input types with TXDIN70-DISPLAY accessory (sold separately)

DIN Rail Conditioners Convert Bridge Inputs to mA or Voltage

The DMD4059 Series converts wheatstone strain bridge sensors, pressure transducers, or load cell signals into process current or voltage. Offered with AC or DC Power.

DIN Rail Isolated Repeater/Splitter for Process Signals.

The DRSL-SP2 is a repeater/splitter that isolates and converts 1 process input to 2 process outputs. DIP switch selectable ranges. Slim housing, high accuracy (0.05%)

DIN Rail Thermocouple Input Signal Conditioners | Low Profile

The DRSL-TC Series are isolated or non-isolated thermocouple input signal conditioners. Accepts Type J and Type K TC's. DIP switch selectable ranges, slim housing.

DIN Rail Load Cell Input Signal Conditioner

The DRF-LC Series Conditioners are load cell input with 0-10V or 4-20mA output. For load cells with 1, 2, or 3 mV/V output. Full scale at 10, 20, or 30mV. Pre-tare jumpers

DIN Rail Temperature Loop Powered Signal Conditioner

The DRSL-TEMP is an output loop powered temperature signal conditioner. Accepts Type J, Type K, or 2, 3 or 4 wire Pt100 RTD input. Slim housing, high accuracy.

DIN Rail Strain Gage/Load Cell Transmitter w/ Bipolar mA/V Output

TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.

Non Isolated Loop Powered DIN Rail RTD Input Conditioner

The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.

DIN Rail Frequency Input Signal Conditioner | Configurable

The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.

DIN Rail Universal Smart Transmitter w/ LED Display

TXDIN101 has thermocouple, RTD, and mV input with 4-20mA output. LED display, configuration TX69-CABLE sold separately required to program via PC.

DIN Rail AC Current and Voltage Transmitter

The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.

Snap In Front Panel Programmer with Modbus over RS-485

The DRST-CM is a programming display for DRST-AC, DRST-DC, DRST-UN & DRST-UR. Supports Modbus over RS-485. Monitors process value on built in display.

DIN Rail Input Loop Powered Isolators w/ 1 or 2 Channel Models

The DRSL-LPI Series Conditioners are 1 or 2 channel analog input loop powered isolators. 1:1 signal ratio, low input voltage drop, slim housing.

Conditionneurs de signaux industriels modulaires

CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.

Mini Rail Mount Input and Output Modules

DR-IO Conditioners convert TTL levels to PLC levels and vice versa. Logic levels switch high level AC/DC circuits and vice versa. Wide logic voltage range and Low profile.

DIN Rail Conditioner Series with Process Input, High accuracy

The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.05% accuracy

DIN Rail Bridge Input Conditioners for Load Cell or Strain Gage

The DRC-4710 and 4720 are DIN Rail bridge input signal conditioners that accept bridge (strain gage, load cell, or voltage) inputs and have 0-10Vdc or 4-20mA outputs.

Conditionneurs de signal à montage rail DIN

DIN Rail Signal Conditioners are essential for accurate data recording in a wide range of industrial, commercial, and laboratory applications. Used to convert input signals from a variety of sources into a uniform output, these conditioners make it possible to measure signals from thermocouples, strain gages, RTDs, load cells, and more.