- 5 Point NIST Traceable Calibration with
59 kOhm Shunt Cal Data - Low Profile
- All Stainless Steel Construction
- Rugged Industrial Design
LC8200-500-2K Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Weight Capacity
Through hole (ID)/ Threaded hole dimension
Height
Measurement Units
Force Direction
Linearity
Electrical Output (Nominal)
OD
Connection Type
Cable Length
SPECIFICATIONS
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Linearity: ± 0.5% FSO
Repeatability: ± 0.1% FSO
Zero Balance: ±2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.009% FSO/°C
Span: ±0.036% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ±5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Linearity: ± 0.5% FSO
Repeatability: ± 0.1% FSO
Zero Balance: ±2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.009% FSO/°C
Span: ±0.036% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ±5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
Rated 4 out of
5
by
Caldwell from
Fixture Required to Avoid Damage
The load cell worked well. My one complaint is that the friction from the nut rotating caused the steel plate we had on the outside to rotate, which in turn caused the load cell to rotate - damaging it's wire. It's easily addressed by either having a fixture, or at the very least having a handle welded to the nut-side plate so it can be held. Lesson learned.
Date published: 2018-06-05
Is the load cell have Integrated Electronics Piezo-Electric device?
This is not a piezoelectric device. Internal circuit is a 350 ohm full strain gage bridge. It is piezoresistive.
Date published: 2021-03-12
If the load to the rim of the sensor is not evenly contacted, will it cause foce inaccuracy? Is the result similar to normal solid axial style?
Thank you for your inquire.
Correct
Because of the uneven surface there will be a offset . How much is hard to tell.
After time you may also get a zero shift.
Date published: 2022-07-01
What's the gage factor on the strain gauge?
Thank you for your inquire.
These sensors use 350 ohm full bridge
Date published: 2022-02-15
Is this a full bridge sensor or do we need to complete the bridge with our data acquisition module?
Yes this load cell is a full bridge configuration. No bridge completion required.
Date published: 2021-03-12
What are the dimensions of the loading surfaces - OD of smaller diameter loading surface and ID of larger diameter loading surface?
A detailed control drawing for the LC8200 Series load cell is available upon request from our applications engineering group. Please email a request to pressure@omega.com and we will email you a copy.
Date published: 2023-10-10
Is this compatible with the vishay DAQ PN mm120-001496?
Thank you for your inquire.
The load cell will put out a linear milli volt per volt output with a 10 volt excitation. As Long as the device will except this output it should be compatible.
Date published: 2022-02-01
i plan on using my own output recording device, what is 2 mV/V mean? is V some form of weight such as kg or lbs? if V is volts, do you have a conversion chart that converts volts to kg?
2mV/V is output sensitivity of the load cell. The means that for every volt excitation power you supply to the load cell you will see a nominal 2 mV output at the full force load applied to the load cell. If you apply the nominal excitation of 10VDC to the load cell you will see a nominal output signal of 0 to 20 mVDC over the load range on the load cell. Each load cell is supplied with a NIST traceable calibration report that tell you the exact mV/V sensitivity of that load cell
Date published: 2020-01-14
Is there a minimum clearance in the ID nominal & tolerances to fit an object of the named diameter? For example, if the ID on a ".675 ID" sensor has an effective min/max of .685"-.700", a perfect .675" cylinder fits w/ at least .010" diametrical clearance
Tolerances for the dimensions on the LC8200 Series are +/- 0.005". A unit with a indicated bore I.D. of 0.625" would have bore tolerance of 0.620" to 0.630"
Date published: 2024-06-17