Appelez-nous au 1-888-826-6342
- Domicile
- Voir Instruments de mesure de débit
- Voir Débitmètres
- Voir Débitmètres à turbine
- DISCONTINUED - Integral or remote signal conditioner
Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.
DISCONTINUED - Integral or remote signal conditioner
Article# FLSC-C3-LIQ-Series
Article# --
- DC or AC Powered
- Pulse and Analog Outputs
- High or Low Alarms (Optional)
- 20 Point Linearization
The FLSC-C3-LIQ is a DC powered, microprocessor controlled transmitter. It outputs a pulse scaled per unit of flow, and analog signal proportional to flow rate. The FLSC-C3-LIQ-AL can be configured with high or low alarms and are designed for integral mounting to the FTB-100, FTB-200, and FTB-400 Series** liquid turbines. ** Visit omega.com/ftb100, omega.com/ftb200, or omega.com/ftb400 for details
Specifications
Input Signal Type: Magnetic pickup, MCP pickup, contact closure, pulse
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc reverse polarity protection
Analog Output: 4 to 20 mA, 1 to 5V 24 mA overflow condition
Load Resistance: Maximum 650 ? at 24 Vdc
Accuracy: ±0.02% of full scale
Temperature Drift: 40 ppm/degree C
Pulse Output: 0 to 5V, 0 to 10V, open collector, AC square. Internal pull up 10 k?. Recommended minimum load resistance 50 k?
Pulse Scaling: Divide by 1, 10 or 100 per flow unit Hi/Lo Alarm (-AL Model) Optional: Relay (2A, 30 Vdc), 0 to 5V, open collector (0.5A, 30V)
Communications: RS232 port for configuration and diagnostics
Operating Temperature: -40 to 85°C (-40 to 185°F)
Specifications
Input Signal Type: Magnetic pickup, MCP pickup, contact closure, pulse
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc reverse polarity protection
Analog Output: 4 to 20 mA, 1 to 5V 24 mA overflow condition
Load Resistance: Maximum 650 ? at 24 Vdc
Accuracy: ±0.02% of full scale
Temperature Drift: 40 ppm/degree C
Pulse Output: 0 to 5V, 0 to 10V, open collector, AC square. Internal pull up 10 k?. Recommended minimum load resistance 50 k?
Pulse Scaling: Divide by 1, 10 or 100 per flow unit Hi/Lo Alarm (-AL Model) Optional: Relay (2A, 30 Vdc), 0 to 5V, open collector (0.5A, 30V)
Communications: RS232 port for configuration and diagnostics
Operating Temperature: -40 to 85°C (-40 to 185°F)
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getReviews, 4ms
- REVIEWS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getContent, 24ms
- QUESTIONS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
XL Series Accessories