21 produits trouvés
thumbnail

Description L'étalon CL3001 d'OMEGA™ est un appareil de précision conçu pour les applications de R&D, de fabrication et d'étalonnage en laboratoire av... Lire la suite

CL3001-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
2   En stock
Not Applicable
100 Vac
Vac
0 to 52 mA
Not Applicable
0.0025%
Temperature
No
Benchtop
Source/Read Thermocouple, RTD, Voltage, Current and Pressure
Not Applicable
RS232
thumbnail

Description The CL300A multifunction thermocouple/mV calibrator combines high accuracy with ease of use. Its accuracy of ±0.3°C (±0.5ºF) includes all errors, at resol... Lire la suite

CL300A-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
Disponible dans 13 semaines
55°C (131°F)
9 Vdc
Battery
Not Applicable
Not Applicable
±0.007% rdg, ±10 µV
Temperature
Yes
Portable
Thermocouple, Millivolt
Not Applicable
Not Applicable
thumbnail

Description Le calibrateur de température portatif OMEGA™ CL3512A, avec une longueur de 2 m et un prix bas, peut simuler les signaux de thermocouples types J/K/T/E. C... Lire la suite

CL3512A-Series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
25   En stock
Not Applicable
Not Applicable
Battery
Not Applicable
Not Applicable
Not Applicable
Temperature
Yes
Handheld
Thermocouple
Not Applicable
Not Applicable
thumbnail

Description Le CL3515R est un calibrateur/thermomètre avec un affichage rétroéclairé à 4 digits. Il a été conçu pour mesurer et simuler une large plage de types de th... Lire la suite

CL3515R-Series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
26   En stock
Not Applicable
Not Applicable
Battery
Not Applicable
17.5 Hours
Thermocouple K/J/T/E/L/U ±(0.05% rdg + 0.5°C) -50 to 1372°C[±(0.05% rdg + 1.0°F) -58 to 2501°F], ±(0.05% rdg + 1.0°C) -50 to -250°C[±(0.05% rdg + 2.0°F)
Temperature
Yes
Portable
Thermocouple
Not Applicable
USB and RS232 Interface with Windows Software
thumbnail

Description With the CL514-PLUS you can check and calibrate all your RTD instruments and measure RTD sensors. Automatic indication of connections on the display for s... Lire la suite

CL514-PLUS-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
1   En stock
60°C (140°F)
Not Applicable
Battery
Not Applicable
50 Hours
±(0.025% of Reading + 0.05 Ω)
Temperature
Yes
Portable
RTD
Not Applicable
Not Applicable
thumbnail

Description With the CL515-PLUS you can check and calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for s... Lire la suite

CL515-PLUS-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
Disponible dans 6 semaines
Not Applicable
Not Applicable
Battery
Not Applicable
50 Hours
From 1 to 10.2 mA external excitation Current ± (0.015% of Reading + 0.05 Ω)
Temperature
Yes
Portable
RTD
Not Applicable
Not Applicable
thumbnail

Description With the CL540ZA you can check and calibrate all your thermocouple instruments. Connect via a miniature thermocouple connector on the top end of the sourc... Lire la suite

CL540ZA-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
Disponible dans 4 semaines
Not Applicable
Not Applicable
Battery
Not Applicable
50 Hours
±(0.015% of reading + 0.006 mV)
Temperature
Yes
Handheld
Thermocouple
Not Applicable
Not Applicable
thumbnail

Description With the CL542-PLUS you can check and calibrate all your thermocouple instruments and measure thermocouple sensors. Calibrate Directly in T... Lire la suite

CL542-PLUS-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
1   En stock
Not Applicable
Not Applicable
Battery
> 20 mA (drives 80 mV into 10 Ω)
50 Hours
± (0.008% of Reading + 0.006 mV)
Temperature
Yes
Portable
Thermocouple, Millivolt
Not Applicable
Not Applicable
thumbnail

Description With the CL541-PLUS you can check and calibrate all your thermocouple instruments and measure thermocouple sensors. Automatic indication of connections on... Lire la suite

CL541-PLUS-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
4   En stock
60°C (140°F)
Not Applicable
Battery
Not Applicable
1 Hour
±(0.008% of Reading + 0.006 mV)
Temperature
Yes
Handheld
Thermocouple, Millivolt
Not Applicable
Not Applicable
thumbnail

Description THERMOCOUPLE CONNECTIONS Simulating or reading thermocouples requires the use of thermocouple or extension grade thermocouple wire. Plug ther... Lire la suite

CL543B-series
Prix Stock Maximum Temperature Measurement Supply Voltage Power Source Input Current Battery Run Time Accuracy Value Measurement Type Batteries Included Form Factor Input Type Style Communications Protocol
4   En stock
Not Applicable
Not Applicable
Battery
Not Applicable
50 Hours
Not Applicable
Temperature
Yes
Portable
Thermocouple, Millivolt
Not Applicable
Not Applicable