Appelez-nous au 1-888-826-6342
Summing Box for Multiple Load Cells
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$686.79 |
10-24 | C$652.45 |
25-49 | C$638.71 |
50-99 | C$611.24 |
100+ | C$597.51 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
JBOX4-ET Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Feature
Weight Capacity
Measurement Units
Force direction
Linearity
Electrical Output (nominal)
Connection Type
Description
A load cell summing box (also known as a J-box) accepts inputs from multiple load cells and combines their outputs into one output that represents the total load. All load cells should have the same capacity and outputs within 3.2% of each other. For larger variances, resistors must be added. Load cells that are trimmed to 0.25% interchangeability or that have output tolerances of less than ±3.2% will work without additional resistors.
Rated 5 out of
5
by
JKBIRD from
Easy Ordering and Fast Shipment
Very easy to order with fast shipping. Would definitely use again
Date published: 2023-05-15
Rated 5 out of
5
by
R Woodward from
4in 1out great product for projects multiple I/Os
well built product even has a rubber seal to protect connections easy wiring instructions
Date published: 2022-02-28
Is there a way to figure out if the potential meter are functioning correctly? I have 3 strain gauges connected and trying to calibrate them to show the same mV/V for the same weight. As shown in the video. The problem is, the mV/V doesn't change.
Jay, it would be better if you called and discussed this issue with tech support. Please contact us at 1800 622 2378
Date published: 2023-07-14
Is a jumper needed between the SIG+ and SIG- if only 3 load cells are being used?
No jumper is needed on the terminals of the unused channel
Date published: 2024-06-17
1. Is this product CSA approved? 2. Can this be installed in Class 1, Div 2 area? 3. What will be excitation voltage for the output? Is it the same as one of the load cells (assuming all load cells are the same)
Thank you for your inquiry, here’s the answers to your question. Is this product CSA approved? NO 2. Can this be installed in Class 1, Div 2 area? NO, This unit would need to be installed behind the barrier 3. What will be excitation voltage for the output, Is it the same as one of the load cells (assuming all load cells are the same) Correct
Date published: 2021-12-03