Appelez-nous au 1-888-826-6342
Thermomètre/Transmetteur infrarouge rapide à fibre optique avec afficheur et sortie tension
Fast Response Infrared Fiber Optic Thermometer/Transmitter with Local Display and Analog Output- For Both Hard to Reach and Polymer Bolt Applications
- Accuracy 1% of Reading
- Models with Temperature Ranges Measuring up to 4500°F (2482°C)
- Current, Voltage, Millivolt or Thermocouple Output
OS1592 Series has been discontinued. Please refer to OS4000 Series.
OMEGA’s new CE marked low cost OS1590 Series infrared fiber optic thermometer/ transmitter system measures temperature ranges up to 4500 F and provides dual analog outputs (4-20 mA, 0-5 VDC, 0-10 VDC, 1 mV/ Degree, J & K T/C) electrically isolated from the DC power supply input. The main Electronics is in a NEMA 4 rated Aluminum housing with a local backlit LCD, built-in Relay, and a 4 position programmable keypad.
SPECIFICATIONS
Temperature Range:
-R1: 260 to 538°C (500 to 1000°F)
-R2: 538 to 1093°C (1000 to 2000°F)
-R3: 1093 to 2482°C (2000 to 4500°F)
Accuracy: 1% of rdg
Repeatability: 0.75% of rdg
Response Time: 25 msec (0 to 63% of final value)
Emissivity: 0.05 to 1.00 adjustable, set via keypad
Spectral Response: 0.8 to 1.8 microns
Analog Output: 1 mV/deg, standard
Second Analog Output: 0 to 5 Vdc, 0 to 10 Vdc, 4 to 20 mA, or Type J or K thermocouple
Display: Backlit Dual LCD
Keypad: 4 position, tactile feedback membrane switch
Calculated Temperature Values: Maximum, minimum, differential High Alarm: Set via keypad with built-in relay
Relay Contact Rating: 5 A @ 28 Vdc
Operating Ambient Temperature: 0 to 50°C (32 to 122°F)
Enclosure: Die cast aluminum, NEMA-4
DIMENSIONS
Main Housing: 8.9 W x 5.6 H x 11.4 L cm (3.5 x 2.2 x 4.5")
Optical Assembly: L1- Lens: 2.5 Dia. x 15.9 cm (1 x 6.25")
L2- Ceramic Tip: 0.47 Dia. x 15.2 cm (0.187 x 6")
L3- Polymer Bolt: 0.95 Dia. x 10 cm (0.375 x 4")
Power: 18 to 36 Vdc
Model Number | Temperature Range | Optical Assembly, Spot Size | Cable Length |
OS1592-L1-R1-1-(*) | 260 to 538°C (500 to 1000°F) | Lens Probe, 6.35 mm @ 203.2 mm (0.25" @ 8") | 1.5 m (5') |
OS1592-L2-R1-(*) | 260 to 538°C (500 to 1000°F) | Ceramic Tip, 152.4 mm (6") Probe | 1.5 m (5') |
OS1592-L3-R1-(*) | 260 to 538°C (500 to 1000°F) | Polymer Bolt, 101.6 mm (4") Probe | 1.5 m (5') |
OS1592-L1-R2-1-(*) | 538 to 1093°C (1000 to 2000°F) | Lens Probe, 6.35 mm @ 203.2 mm (0.25" @ 8") | 1.5 m (5') |
OS1592-L1-R2-2-(*) | 538 to 1093°C (1000 to 2000°F) | Lens Probe, 4.83 mm @ 508 mm (0.19" @ 20") | 1.5 m (5') |
OS1592-L1-R2-3-(*) | 538 to 1093°C (1000 to 2000°F) | Lens Probe, 1.93 mm @ 152.4 mm (0.076" @ 6") | 1.5 m (5') |
OS1592-L2-R2-(*) | 538 to 1093°C (1000 to 2000°F) | Ceramic Tip, 152.4 mm (6") Probe | 1.5 m (5') |
OS1592-L3-R2-(*) | 538 to 1093°C (1000 to 2000°F) | Polymer Bolt, 101.6 mm (4") Probe | 1.5 m (5') |
OS1592-L1-R3-2-(*) | 1093 to 2482°C (2000 to 4500°F) | Lens Probe, 4.83 mm @ 508 mm (0.19" @ 20") | 1.5 m (5') |
OS1592-L1-R3-3-(*) | 1093 to 2482°C (2000 to 4500°F) | Lens Probe, 1.93 mm @ 152.4 mm (0.076" @ 6") | 1.5 m (5') |