Appelez-nous au 1-888-826-6342
Sondes Thermocouples Avec Tête de Protection Industrielles
Thermocouple Probes with Industrial Protection Heads
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$137.88 |
10-24 | C$130.99 |
25-99 | C$124.09 |
100-499 | C$117.20 |
500-999 | C$110.30 |
1000+ | C$103.41 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Fabrication - Câble de tolérance de Classe 1
- Les Sondes sont testées individuellement pour la pression et l'isolation
- Gaines Standards - 310, 321, Inconel ou SuperOMEGACLAD™XL MI (isolation minéral). D'autres matériaux disponibles.
- Longueurs Standards 150, 300 et 500mm. D'autres longueurs disponibles sans délai.
- Diamètres de Sonde Standards 1.5, 3.0, 4.5 et 6mm. D'autres diamètres de sonde disponibles.
- Filetage 1/2" BSPT Standard. D'autres filetages disponibles.
- Soudure Chaud de Thermocouple: fondée, isolée ou exposée
(*) DESIGNE LE TYPE DE TETE DE PROTECTION - NB5 = Tête de protection en Fonte
- NB6 =Tête en Aluminium DIN Forme B
- NB9 = Tête en Fibre de Verre
- NB11 = Tête Miniature en Aluminium
- NB12 = Tête en Aluminium Standard
- Cliquez ici pour tous les types de tête de thermocouple
NB3-CASS-14U-2 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.
Thermocouple Type
Process Temperature Range
Sensor Application
Process Connection Size
Sheath Material
Junction Type
Probe Diameter
Probe Length
Termination Connection Type
Additional Feature
Category
Description
Ces ensembles thermocouples industrielles sont fabriqués à partir de câble isolant minéral (MI) de tolérance de la Class 1. La gaine semi-rigide peut être déformée, la gaine de minéral courbé pour répondre à de nombreuses applications. Ces modèles offrent une grande variété de têtes de protection et raccordements de process pour satisfaire les exigences d'environnement de la plupart des applications. Ils sont équipés en standard d'une process de raccordement 1/2 BSPT (R1/2), consultez le PDF ou la table de "Construction de référence" ci-dessous pour savoir comment spécifier le filetage de process de G1/2 ou G1/4.Les exemples des prix des modèles les plus courants sont donnés dans le tableau "Pour Commander". Utilisez la tableau de "Construction d'une Référence" ci-dessous pour déterminer le prix des autres modèles.
Pour obtenir les caractéristiques complètes de ces produits, consultez le PDF "Specifications" dans "Liens Associés- Produits Reliés" ci-dessous.
Rated 5 out of
5
by
Anonymous from
GREAT COMPANY
Staff was prompt and courteous with order sent to them and shipped out product right away.
Date published: 2024-05-17
Rated 5 out of
5
by
Mattcerk from
Easy
Fast shipping! Website easy to use. Will be ordering again
Date published: 2023-08-12
Rated 4 out of
5
by
Claudio Braga from
Good
high quality, fast delivery, reasonable price, works perfectly
Date published: 2023-06-21
Rated 5 out of
5
by
JFarris13 from
Great Service!
Omega always provides quick answers and has competitive pricing.
Date published: 2023-04-03
Rated 5 out of
5
by
Project Manager ENG from
Just needed some thermocouples now
Quick Ship no issues, what can I say it is a thermocouple
Date published: 2023-03-15
Rated 5 out of
5
by
Dan R from
Thermocouple
Easy to install works great make sure to order the wires with it
Date published: 2023-01-08
Is there a manual I can download?
Thank you for your inquiry JohnW. We don't have a manual for this thermocouple. We only have the data sheet. Here is the link to the data sheet: https://assets.omega.com/pdf/test-and-measurement-equipment/temperature/sensors/thermocouple-probes/NB1-ICIN_INDUST_TC.pdf
Date published: 2021-09-16
CAN YOU USE REGULAR 1PR 16 FROM RTD TO CONTROLL PANEL
Thank you for your inquiry JIMBO76. I’m not clear on what you are asking. This is a thermocouple and it seems like you are asking about an RTD. If you are asking about the compatibility of an RTD or a thermocouple with a controller, it would depend on the individual controller. If this didn’t answer your question or if you have any further questions please call us at 1-888-826-6342
Date published: 2022-01-20
Would this be a 4-20 ma signal?
Thank you for your inquiry BobbyG. The NB2-ICSS-14U-12's output is in mV. You can get an output in mA if you connect this probe to a transmitter like the TX93-K2 whose output is in mA.
Date published: 2024-05-05
What is the input voltage requirement for the thermocouple?
Thank you for your inquiry SB16. There is not fixed voltage value for thermocouples because the voltage changes as the temperature increases or decreases. The term "input voltage" does not apply to a thermocouple as it is a self-powered device.
Date published: 2024-05-05
Where can I find resolution or accuracy values for any product? Its not given in the tech datasheet.
Hi Rahul,
The data sheet includes a note at the top right indicating the probes meet or exceed SLE specification. For details on thermocouple SLE;
https://www.omega.com/en-us/colorcodes
Resolution is determined by the measuring instrument since the output is a micro volt level signal generated by thermocouple effect.
Best regards,
OMEGA
Date published: 2023-12-11
How can I check calibration?
Thank you for your inquiry. Please you can order these parts with calibration using the CONFIGURATE NOW button.
Date published: 2021-05-28
What device can I use to get temperature readings from an NB2-ICSS-14U-4 thermocouple? If I can use a multimeter to get a reading then how do I translate that reading to a temperature?
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:00AM - 5:30PM EST).
Date published: 2023-07-17
What is the accuracy and resolution of thermocuple model NB12-CPSS-14G-6?
Thank you for your inquiry. NB12-CPSS-14G-6 does not have resolution, the accuracy is +/- 0.5°C or 0.4%, whichever is greater.
Date published: 2023-12-05