PST rejoint DwyerOmega. En savoir plus>
Thermocouples à Déconnexion Rapide Avec Connecteurs Miniatures.
Quick Disconnect Thermocouples with Miniature Connectors
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$59.07 |
10-24 | C$56.12 |
25-99 | C$53.16 |
100-499 | C$50.21 |
500-999 | C$47.26 |
1000+ | C$44.30 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Longueurs 150mm et 300mm en Stock
- Diamètres de Gaine de 1 à 3mm.
Cliquez ici pour thermocouples de diamètres 0,25 à 0,75mm - Gaine: Acier Inox, Incone, SuperOMEGACLAD™XL
- Soudure Chaud: à la Masse, Isolée , Nue
- Terminaison par Connecteur Miniature
- Connecteur et serre câble inclus- gratuit
- Fabrication: Câble de tolérance de Classe1
- Corps de connecteur en Nylon verre-rempli, utilisable jusqu'à 220°C
- Sondes Testée- les sondes sont testée individuellement pour la pression et l'isolation
- Longueurs Personnalisées Disponibles
KMQSS-IM100U-150 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.
Thermocouple Type
Process Temperature Range
Sensor Application
Sheath Material
Junction Type
Probe Diameter
Probe Length
Connector Color Code Standard
Additional Feature
Sensor Type
Connector Style
Please use the QD product configurator to configure a replacement product
Rated 5 out of
5
by
elbird from
Great service!
We order from Omega on a regular basis. They almost always have the exact part we were looking for and we always receive our orders in a very timely manner in the condition expected. Top notch.
Date published: 2017-07-06
Rated 5 out of
5
by
Rachel Castellano from
Timely shipping for a timely needed product
Thermocouples that arrive on time, with no abnormalities and never have to be returned.
Date published: 2023-07-19
Rated 5 out of
5
by
JamesM from
Sturdy and Accurate
Have used these products over the years and they have always been reliable and sturdy despite the abuse they get.
Date published: 2022-09-12
Rated 5 out of
5
by
Dock from
Quick Disconnect Thermocouples
Much like all of the other OMEGA products I have used over the years these TC's are a GREAT PRODUCT! Your new website is awful!
Date published: 2020-05-13
Rated 3 out of
5
by
MacKKev from
Disappointed that the mini connector is separate.
My company has been purchasing this Tcouple for decades. The latest batch came with no connectors. Nobody informed us at time of purchase, and we were charge for rush shipping to a customer that was unhappy with the delay.
Date published: 2018-09-16
Rated 5 out of
5
by
VJTC from
Accurate
Works well for what I needed it for - pharmaceutical products.
Date published: 2024-12-05
Rated 5 out of
5
by
SteveSS from
Quality branded products and fantastic service
Excellent product! Fast delivery and friendly service!
Date published: 2024-10-14
Rated 5 out of
5
by
T R C from
Exactly as pictured and arrived quickly
Exactly as pictured and arrived quickly. Worked perfectly for need.
Date published: 2024-08-12
What is the actual bead diameter of the 1/16" sheath exposed junction probes?
Thank you for your inquiry! Unfortunately, we don't have data on the bead diameter for each probe. However, the length of the exposed junction is approximately 1/4".
Date published: 2021-07-19
How do I ensure the accuracy of a KMQSS-062U-12 thermocouple? Is there a standard calibration, and can I access documentation of it?
You can purchase a 3 point NIST traceable calibration report with your probe. Full report will ship with your probe. Please request pricing and lead time quotation from the sales group.
Date published: 2020-02-10
Hello, I want to access the calibration document of these thermocouples. And their uncertainty if it is possible
Thank you for your inquiry. That information can only be acquired when requesting a CAL-3 Calibration Certificate. You can do so by using the CONGIFURE NOW button.
Date published: 2021-02-23
I recently purchased 10 KMQSS-125G-6-CL5. These are calibrated thermocouples. Can I get a copy of a typical calibration certificate.
Hi PMCJR
Thank you for the inquiry. Following link provides details of the CL5 option including points provided.
https://www.omega.com/en-us/calibration-temperature-page
Best regards
OMEGA
Date published: 2022-06-01
What is the tolerance on the diameter of a KMQSS-062U-12?
Thank you for your inquiry. The tolerance of the diameter is ±0.001"
Date published: 2022-07-15
What are the pressure limitations of 0.125" 304-SS thermocouple probes?
Hi GBrillo
Thank you for the inquiry. These do not have a pressure rating. For a pressurized line please consider a thermowell and probe or our "pipe plug" style thermocouple. Pipe plug style ( grounded or ungrounded) have a pressure rating of 2500 psi at ambient temperature.
https://www.omega.com/en-us/sensors-and-sensing-equipment/temperature/sensors/thermocouple-probes/tc-npt/p/TC-K-1-8NPT-G-72
Best regards
OMEGA
Date published: 2020-04-02
Does heat conduction along the sheath throw off temperature reading? If part of the sheath is under higher temperature than the tip, would this conduction cause the reading at the tip to be higher than it should be?
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:30PM EST).
Date published: 2023-05-25