Hollow Tube Thermocouple Probe

C$92.91

Article# HTTC36-T-316U-2.5-SB

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$92.91
10-24 C$88.26
25-99 C$83.62
100-499 C$78.97
500-999 C$74.33
1000+ C$69.68

En stock

Délai de livraison (si pas en stock): 5 semaines
Hollow Tube Thermocouple Probe HTTC36-T-316U-2.5-SB HTTC36-T-316U-2.5-SB
  • Fils thermocouple gainés de Téflon, de longueur totale 900mm
    moulés à l'époxy sur 150mm dans un tube de protection en acier inoxydable
  • Jusqu'à 230°C
    en option: gaine en soie de verre, jusqu'à 480°C
  • Diamètre de sonde: 1,6mm, 3,2mm, 4,75 mm, et 6,35mm
  • Thermocouple J, K, T, E ou N de classe 1
  • Surgainage en acier inoxydable en option

HTTC36-T-316U-2.5-SB Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Thermocouple Type
Process Temperature Max
Process Temperature Range
Junction Type
Probe Diameter
Probe Length
Cable Insulation
Wire Gauge
Cable Length
Termination Connection Type
Color Code Standard
Category
Process Temperature Unit
Process Temperature Min
Sensor Application
Sheath Material


Description

Cette variante de la sonde type TJ se caractérise par une taille plus compacte et un coût abordable. Elle est conçue pour les applications où les contraintes mécaniques sont limitées.

Les prix des modèles les plus courants sont donnés dans le tableau "Pour commander". Utilisez la table de "Construction d'une référence" ci-dessous pour déterminer le prix des autres modèles.

Pour obtenir les caractéristiques complètes de ces produits, consultez la notice commerciale par le lien en bas de cette page.
loading all models
loading all reviews
Rated 5 out of 5 by from MY 6" THERMOCOUPLES The performance of the thermocouples is very acceptable!!! Thanks OMEGA...
Date published: 2015-12-06
Rated 5 out of 5 by from Product Availability Importance Received product and engineering will use for testing
Date published: 2024-08-29
Rated 2 out of 5 by from Product explanation Product not explained well in specifications area.
Date published: 2024-05-21
Rated 5 out of 5 by from The thermocouple probe I have been waiting for Great quality probe. Was packaged well and arrived quickly.
Date published: 2024-01-08
Rated 4 out of 5 by from Thermocouple review omega Great design and product for the money none none no
Date published: 2022-09-17
Rated 4 out of 5 by from It works Used for regulating pallet temperture for verification purpose
Date published: 2022-09-08
Rated 5 out of 5 by from Type K meets specifications This probe works as advertised and is well within the conformance specifications for a Type K thermocouple. Don’t bother with the cheap knockoffs. Those devices are inaccurate. This is the real deal.
Date published: 2020-11-08
Rated 5 out of 5 by from Otter-man Rating I bought these a few years back for use in an oven, one for the lower area and one for the upper, as additional temperature monitoring. The work really well.
Date published: 2020-08-10
  • y_2024, m_12, d_4, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_11
  • loc_en_CA, sid_HTTC36-T-316U-2-5-SB, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
loading all QA

Will this work connected directly to an RCA cable and connected to a Quanser board for use with Matlab Simulink?

Asked by: UMD Student
I'm not an expert but I know enough to say it depends on you definition of "work". If you require highly accurate measurement, then no. If you need "close enough", then yes. A T/C is a junction of dissimilar metals. At that junction a voltage (mV) is generated which relatively linear to temperature change, this makes it easy to convert to temp. So, each connection that is made in the sensing circuit of dissimilar metals creates a thermocouple (ie- RCA jack; Sn, Ni or Au plated brass to Chromel + & Alumel - of a K type thermocouple). The ambient temperature where these connection are made will effect the overall mV value generated in the circuit. -good luck
Answered by: ElectricBill
Date published: 2020-12-07
  • y_2024, m_12, d_4, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_HTTC36-T-316U-2-5-SB, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 44ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration