Sondes à RTD (Pt100) pour usage général sans jonction de transition entre le câble et le chemisage
RTD Probe with Insulated Wire and Shrink-Tube Support
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$200.07 |
5-9 | C$190.07 |
10-24 | C$186.07 |
25-49 | C$178.06 |
50-99 | C$174.06 |
100+ | C$170.06 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Transition du chemisage directement au câble (pas de jonction de transition)
- Design compact pour les applications à espace restreint
- Longueurs standards: 6", 12", 18" et 24" ainsi que 150, 300, 450 et 600 mm
- Gamme de température: -200 à 600°C (260°C pour le câble et les 2 derniers pouces de la sonde)
- Diamètres: 1/8", 3/16" et 1/4" ainsi que 3, 4.5 et 6 mm
- La sonde contient un élément de platine de 100 ohms de précision Classe A DIN (alpha = 0.00385 ohm/ohm/°C)
- Configuration à 2, 3 ou 4 fils disponible
OPTIONS - Gaine thermo-rétractable avec réducteur de tension à la fin du chemisage
- Sonde isolée au Teflon PFA
- Gainage du fil en acier inoxydable pour les sondes de 3/16" et de 1/4" de diamètre
- Alpha = .00392
- Longueurs de sonde non-standards
PR-10E-3-100-1/8-6 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.
Process Temperature Min
Process Temperature Max
Process Temperature Range
Nominal Output
Number Of Wires
Probe Diameter
Probe Length
Cable Length
Additional Feature
Category
Process Temperature Unit
Sensor Application
Accuracy
Sheath Material
Cable Insulation
Wire Gauge
Termination Connection Type
Description
Cette sonde à RTD à usage général passe directement du chemisage au câble de 40 pouces (1 mètre) sans l'utilisation d'une jonction de transition en métal. Ce design permet d'avoir une sonde plus compacte lorsque la limitation de l'espace est un facteur. Veuillez prendre note que l'endroit où le fil sort du chemisage ne sera pas aussi durable que sur la sonde modèle PR-11, qui possède une jonction de transition en métal et un réducteur de tension à ressort.Pour des options spéciales, veuillez consulter notre département des ventes pour les prix et les disponibilités.
Les prix des modèles les plus courants sont donnés dans le tableau "Pour commander". Utilisez le "Tableau Constructeur de référence" ci-dessous pour déterminer le prix des autres modèles.
Pour obtenir les caractéristiques complètes de ces produits, consultez les "Liens associés - Produits reliés" sous le "Tableau Constructeur de référence".
Rated 3 out of
5
by
UC Davis Medical Center from
RTD Probe review
The connection point from the probe to the wire is a weak point that has broken a few times. We have repaired and/replaced this probe multiple times. Also the connection to the thermometer has failed as well.
Date published: 2021-03-02
Rated 4 out of
5
by
648965742 from
Good for static measurement, response time varies
Easy to use, accurate devices. Warning, I saw different response times between the two devices I ordered when the temperature was changing rapidly. One responded to an 80 C difference in ~ 1 min, the other took 5 min to stabilize.
Date published: 2020-07-20
Rated 3 out of
5
by
paddy from
Nice design - Required proprieatay connector
I bought an Omega data logger with 4 thermocouple inputs and 2 RTD connections. The device worked right out of the box - is easy to use and record with. Unfortunately Omega has designed the data logger so that we have to use their proprietary connectors , almost like an earphone jack, for the RTDs. My master technician tried to solder these connects and messed one of them up. Called up Omega. 3 week lead time, and no they would not replace the connector. a Little disappointed on that front. Very limited instructions on how to solder this connector. We guessed as to what terminal goes to what RTD wire and took an educated guess. Lucky for us our guess was right.
Date published: 2018-03-26
Rated 5 out of
5
by
Good One from
AMAZING AND HELPFUL
Exactly what we needed and Sales associate was extremely helpful.
Date published: 2024-11-11
Rated 5 out of
5
by
M Leonard from
Great Company, Great Product
Great product, exactly as expected. The Team at Omega is easy to work with. Great customer service. 10/10!
Date published: 2024-09-19
Rated 5 out of
5
by
DinRail from
Great product
Consistently reliable temp monitoring. Easy to install and works great in a wide range of areas
Date published: 2023-09-24
Rated 5 out of
5
by
Union College from
RTD Probe
great product and will purchase more as time goes on
Date published: 2023-05-19
Rated 5 out of
5
by
Anonymous from
1,000 Ohm RTD Thermocouple
Omega was fantastic to work with. I needed a single, 1,000 Ohm thermocouple to repair an old dental oven and they helped me determine what I needed and I had a new thermocouple in a month. Oven works like new now.
Date published: 2022-11-05
What is the accuracy of the probe?
Thank you for your inquiry Nathan2. The accuracy of the PR-10 series RTD probes is Class A accuracy conforming to IEC 60751. For more information, please review this link: https://assets.omega.com/tech-ref-legacy-pdfs/z251.pdf
Date published: 2022-12-03
The RTD I got have two red leads and one white leads. I also have this RTD connector from Omega (MTP-U-F); the three prongs are labeled cp+, cp-, and ground. What is the correspondence between these two componenets?
Thank you for your inquiry. The two red leads go into the cp+ and cp- terminals of the connectors while the white lead goes into the ground terminal
Date published: 2023-10-14
What is the difference between your red red white 3 wire rtd and your black black red 3 wire rtd?
Thank you for your inquiry. There is no difference in functionality, only color.
Date published: 2023-04-26
How long is the sensor portion compared to the wire length?
Thank you for your inquiry. The sensor is placed right at the tip of the probe.
Date published: 2023-10-02
What is the maximum pressure rating for this RTD probe?
Omega does not place a pressure rating specification on theses probes.
Date published: 2024-04-29
Can these probes be bent 90 deg at about the midpoint and still function properly?
Thank you for your inquiry BigThermalGuy. Unfortunately, the PR-10 series cannot be bent as that will damage the sensor and it will not work properly. Please review the PR-26 series which can be bent. Here is the link: https://www.omega.com/en-us/temperature-measurement/temperature-probes/probes-with-integral-connectors/p/PR-26-Standard
Date published: 2023-10-14
What is the MTBF of these RTDs? Specifically looking at Naval Sheltered environments.
Thank you for the inquiry. Please forward this question to TEMP@OMEGA.COM.
Best regards
OMEGA
Date published: 2023-08-30
What is the tolerance on the diameter and length?
Thank you for the inquiry. Please forward this question to TEMP@OMEGA.COM
Best regards
OMEGA
Date published: 2022-03-21