Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

Sondes à RTD en platine (Pt100) à usage général avec réducteur de tension en métal

Fine Diameter 1/16" and 1.5mm RTD (PT100) Probes

C$271.70

Article# PR-11-2-100-1/16-12-E

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$271.70
10-24 C$258.12
25-99 C$244.53
100-499 C$230.95
500-999 C$217.36
1000+ C$203.78

En stock

Délai de livraison (si pas en stock): 6 semaines
Fine Diameter 1/16" and 1.5mm RTD (PT100) Probes PR-11-2-100-1/16-12-E PR-11-2-100-1/16-12-E
  • Sonde à RTD (Pt100) à usage général contenant un élément de platine de 100 ohms à 0°C
  • Précision Classe A IEC/DIN (± 0.15°C à 0°C)
  • Coefficient de température : Alpha = 0.00385 ohm/ohm/°C nominal
  • Diamètres: 1/8", 3/16" et 1/4" ainsi que 3, 4.5 et 6 mm
  • Longueurs standards: 6", 9", 12", 18" et 24" ainsi que 150, 225, 300, 450 et 600 mm pour satisfaire la majorité des applications
  • Fourni avec un minimum de 36" de fils 26 AWG à 3 conducteurs multibrins en cuivre plaqué nickel avec une isolation et un recouvrement en PFA
  • La majorité des configurations est disponible en inventaire

PR-11-2-100-1/16-12-E Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Probe Length
Cable Insulation
Cable Length
Termination Connection Type
Category
Process Temperature Unit
Process Temperature Min
Process Temperature Max
Process Temperature Range
Sensor Application
Accuracy
Nominal Resistance
Number Of Wires
Sheath Material
Probe Diameter
Wire Gauge


Description

Une sonde à RTD à usage général avec une jonction de transition. Fourni avec 36" de fils recouvert de PFA. Les longueurs de sondes standards sont de 6, 12, 18 et 24 pouces. Les diamètres standards sont de 1/8, 3/16 et 1/4 de pouce. Une terminaison avec fils dénudés est standard.

Consultez notre département des ventes pour des sondes de longueurs différentes et pour des longueurs de fils différentes.

Les prix des modèles les plus courants sont donnés dans le tableau "Pour commander". Utilisez le "Tableau Constructeur de référence" ci-dessous pour déterminer le prix des autres modèles.

Pour obtenir les caractéristiques complètes de ces produits, consultez les "Liens associés - Produits reliés" sous le "Tableau Constructeur de référence".

loading all models
loading all reviews
Rated 3 out of 5 by from Good, but fragile The first one i bought became intermittent after a couple weeks of use. It has a couple of shallow clamp marks from the pass thru fitting and a slight bend to it, but it seems that was enough to do it in. Bought another and was particularly careful with it, finished testing, still good. Accurate and responsive, but fragile.
Date published: 2017-06-05
Rated 5 out of 5 by from great product perfect size for our needs..quickly ordered and shipped
Date published: 2023-04-14
Rated 5 out of 5 by from Great Probe Probe is working great if not bumped against hard object, or terminals soldering is bad to inside the connector. I am not letting anybody else to use that probe to avoid unnecessary breakage and replacement. It is so delicate. Some of them are working great for a long time. Some do not stand to the next calibration date.
Date published: 2020-09-04
Rated 5 out of 5 by from Great Quality We have used these for years. They work well and are quite durable.
Date published: 2018-09-25
Rated 5 out of 5 by from Good product I bought one and it´s very well, the delivery was very quick and the product was perfect.
Date published: 2018-03-04
  • y_2024, m_3, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_CA, sid_PR-11-2-100-1-16-12-E, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
loading all QA

I purchased 5 of RTDs PR-11-2-100-1/8-6-E. The temperature readings were 5-9 degC out when connected to CS8DPT controller. Are these RTD need to be calibrated separately? what are Calibration options? calibration frequency?

Asked by: nghige
Thank you for your inquiry. Please contact our Temperature Department or email your questions to temp@omega.com
Answered by: Application Engineer JB
Date published: 2020-12-02

Hi, is this product's probe waterproof?

Asked by: ahnka
Thank you for your inquiry ahnka. Yes, only the sheath itself is waterproof. The transition joint is not waterproof.
Answered by: Application Engineer SP
Date published: 2022-07-28

What is the tolerance on the sheath outer diameter? I have PR-11-2-100-1/16-6-E and it will be inserted in stainless steel 316 with hole at 0.066" hole +/- 0.005". With calipers I get 0.063" consistently along probe length.

Asked by: Nando
Thank you for your inquiry. The sheath tolerance for a 1/16" diameter probe is ±0.001.
Answered by: Application Engineer CB
Date published: 2022-11-29

I configured an RTD and this is the part number the configurator gave me PR-11-2-100-1-8-4-E-SB-120. What does the -SB mean?

Asked by: markgold
This means the Steel Braid additional feature. Please feel free to contact our Tech Support any time if you have any further questions. Thank you!
Answered by: Jane
Date published: 2020-09-14

Two questions: 1) Are these compatible with Swagelok compression fittings (on the probe)? 2) Are these bendable at all (even 5-10 deg)?

Asked by: SwagelokFan
Thank you for your inquiry SwagelokFan. For the compression fitting to work with the probe the inner diameter of the fitting must match the diameter of the probe. Unfortunately, they are not bendable.
Answered by: Application Engineer MC
Date published: 2023-08-11
  • y_2024, m_3, d_27, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_PR-11-2-100-1-16-12-E, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
fr-CA
fr