Appelez-nous au 1-888-826-6342
Sonde à joint de transition pour thermocouple robuste avec tresse en acier inoxydable sur fil de liaison en PFA et connecteur mâle / pince de câble miniature
Rugged Thermocouple Transition Joint Probe with Stainless Steel Braid over PFA Lead Wire and Miniature Male Connector/Cable Clamp
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$109.31 |
10-24 | C$103.84 |
25-99 | C$98.38 |
100-499 | C$92.91 |
500-999 | C$87.45 |
1000+ | C$81.98 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Stainless Steel Overbraid Resists Abrasions and Cuts, yet Remains Flexible
- 1 m (40 in.) Lead Length
- 304 SS and Inconel® 600 sheaths. Additional Sheaths Available: 310 SS, 316 SS, 321 SS and Super OMEGACLAD™ XL
- Manufactured with OMEGACLAD™ Compacted Mineral Insulation Cable for Long-Lasting, Low-Drift Performance in Harsh Conditions!
TJ36-CAXL-316G-6-SB-SMPW-M Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.
Thermocouple Type
Process Temperature Max
Process Temperature Range
Sensor Application
Sheath Material
Junction Type
Probe Diameter
Probe Length
Category
Process Temperature Unit
Process Temperature Min
Cable Insulation
Wire Gauge
Cable Length
Termination Connection Type
Color Code Standard
Additional Feature
For long life, drift-free operation, choose Super OMEGACLAD™ XL mineral insulated thermocouple cable and our rugged transition joint probes, which are available in Type K and N calibrations. PFA lead wire with a stainless steel overbraid resists abrasions and provides a cost-effective solution for environmental temperatures to 260°C (500°F). See the highlighted section in the table.
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number. See ordering examples below.
View the Thermocouple Accuracy and Color Code charts
Calibration ANSI Code | Sheath Materials | Sheath Dia. mm (in.) | T/C Junction Upper Temp. °C (°F) | Model Number (See notes, below) |
K Chromega® - AL | 304SS | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 899 (1650) 899 (1650) 899 (1650) 899 (1650) | TJ36-CASS-116(*)-(**)-SB-SMPW-M TJ36-CASS-18(*)-(**)-SB-SMPW-M TJ36-CASS-316(*)-(**)-SB-SMPW-M TJ36-CASS-14(*)-(**)-SB-SMPW-M |
INC600 | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 921 (1690) 1071 (1960) 1149 (2100) 1149 (2100) | TJ36-CAIN-116(*)-(**)-SB-SMPW-M TJ36-CAIN-18(*)-(**)-SB-SMPW-M TJ36-CAIN-316(*)-(**)-SB-SMPW-M TJ36-CAIN-14(*)-(**)-SB-SMPW-M | |
Super OMEGACLAD™ XL | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 1038 (1900) 1149 (2100) 1204 (2200) 1204 (2200) | TJ36-CAXL-116(*)-(**)-SB-SMPW-M TJ36-CAXL-18(*)-(**)-SB-SMPW-M TJ36-CAXL-316(*)-(**)-SB-SMPW-M TJ36-CAXL-14(*)-(**)-SB-SMPW-M | |
J Iron- Constantan | 304SS | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 441 (825) 521 (970) 621 (1150) 721 (1330) | TJ36-ICSS-116(*)-(**)-SB-SMPW-M TJ36-ICSS-18(*)-(**)-SB-SMPW-M TJ36-ICSS-316(*)-(**)-SB-SMPW-M TJ36-ICSS-14(*)-(**)-SB-SMPW-M |
T Copper- Constantan | 304SS | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 260 (500) 316 (600) 371 (700) 371 (700) | TJ36-CPSS-116(*)-(**)-SB-SMPW-M TJ36-CPSS-18(*)-(**)-SB-SMPW-M TJ36-CPSS-316(*)-(**)-SB-SMPW-M TJ36-CPSS-14(*)-(**)-SB-SMPW-M |
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number. See ordering examples below.
View the Thermocouple Accuracy and Color Code charts


Rated 4 out of
5
by
Bmralex from
Diameter is wrong
The probe works great, however the tolerance for the diameter is too wide. I ordered 1/16" probe, but it does not fit into 1/16" lumen. I measured the diameter of the probe with a digital caliper and the diameter was 1.64mm instead of 1.59mm (1/16")
Date published: 2017-10-12
Rated 5 out of
5
by
Paula Udwin from
Rugged and Sturdy
Omega sells quality products that can be relied on.
Date published: 2023-06-29
Rated 5 out of
5
by
Administrative Assistant from
Great Product
Does the job. Easy to use. Would definitely recommend.
Date published: 2023-05-12
Rated 1 out of
5
by
E Nelson from
Flimsy. Inaccurate readings after a month.
Flimsy probe. Bent with minimal force during product placement. Made final desired use sub optimal.
After a month of use, probe now reads 30 to 40 degrees below actual temp.
My most expensive thermocouple and it's useless.
Date published: 2023-02-14
Rated 5 out of
5
by
Papapoirier from
Best out there
great quality. These last a long time and are very accurate
Date published: 2022-11-29
Rated 5 out of
5
by
Tony K from
Good Quality
Good quality, work great, fast shipping, would order from them again
Date published: 2021-04-16
Rated 3 out of
5
by
Anonymous from
Be cautious.
Does what it is designed to do, I just wish the one in the pic is the one that is sent. The probe sent is really flimsy and bends easily. Have to be really careful with it.
Date published: 2020-10-18
Rated 5 out of
5
by
Barth from
Perfect
I really appreciate the quality of your thermocouples as well as your customer service!
Date published: 2020-08-07

Can the probe be bent?
Hi Joelle,
Thank you for the inquiry. Yes this probe can be bent. A bend radius guideline is bend radius greater then 3 x diameter.
Best regards
OMEGA
Date published: 2022-05-07
Will this come NIST traceable calibrated? Can it be Accredited Calibration... with uncertainties?
Hi SuperJeff,
Thank you for the inquiry. We offer NIST traceable calibration as an add-on. You can generate part# and price using the "Configure Now" button at the top of this page. We are not accredited ISO17025 unfortunately.
Best regards
OMEGA
Date published: 2022-01-18
Does this come with or be made with a 10' lead?
Thank you for your inquiry. This come with a 40 inch lead. You can use the CONFIGURE NOW button to customize the lead length
Date published: 2020-02-14
what is the pressure rating for these t/c and are they the same for every type?
Thank you for your inquiry. Pressure ratings for these sensors are dependent on the fitting's pressure rating they are used with.
Date published: 2021-04-08
At what point on probe is temperature measured? At the very tip?
Yes, the temperature measurement is taken at the tip of the probe.
Date published: 2020-08-31
What is the temperature rating for the Ultra High Temperature Silica Ceramic With Inconnel Overbraid?
Thank you for your inquiry Arden. The temperature rating for the Ultra High Temperature Silica Ceramic With Inconnel Overbraid wire would be 815°C (1500°F) maximum.
Date published: 2022-12-03
what's the response time
Thank you for your inquiry! Response time will vary based on a number of factors including junction type and probe diameter. This page is a great resource for determining thermocouple response time:
https://www.omega.com/en-us/resources/thermocouples-response-time
Date published: 2021-04-01