Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

Sondes à RTD (Pt100) pour usage général sans jonction de transition entre le câble et le chemisage

RTD Probe with Insulated Wire and Shrink-Tube Support

C$105.26

Article# PR-10L-3-100-1/4-6

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$105.26
5-9 C$100.00
10-24 C$97.89
25-49 C$93.68
50-99 C$91.58
100+ C$89.47

En stock

Délai de livraison (si pas en stock): 5 semaines
RTD Probe with Insulated Wire and Shrink-Tube Support PR-10L-3-100-1/4-6 PR-10L-3-100-1/4-6
  • Transition du chemisage directement au câble (pas de jonction de transition)
  • Design compact pour les applications à espace restreint
  • Longueurs standards: 6", 12", 18" et 24" ainsi que 150, 300, 450 et 600 mm
  • Gamme de température: -200 à 600°C (260°C pour le câble et les 2 derniers pouces de la sonde)
  • Diamètres: 1/8", 3/16" et 1/4" ainsi que 3, 4.5 et 6 mm
  • La sonde contient un élément de platine de 100 ohms de précision Classe A DIN (alpha = 0.00385 ohm/ohm/°C)
  • Configuration à 2, 3 ou 4 fils disponible

    OPTIONS
  • Gaine thermo-rétractable avec réducteur de tension à la fin du chemisage
  • Sonde isolée au Teflon PFA
  • Gainage du fil en acier inoxydable pour les sondes de 3/16" et de 1/4" de diamètre
  • Alpha = .00392
  • Longueurs de sonde non-standards

PR-10L-3-100-1/4-6 Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.

Process Temperature Min
Process Temperature Max
Process Temperature Range
Nominal Output
Number Of Wires
Probe Diameter
Probe Length
Cable Length
Additional Feature
Category
Process Temperature Unit
Sensor Application
Accuracy
Sheath Material
Cable Insulation
Wire Gauge
Termination Connection Type


Description

Cette sonde à RTD à usage général passe directement du chemisage au câble de 40 pouces (1 mètre) sans l'utilisation d'une jonction de transition en métal. Ce design permet d'avoir une sonde plus compacte lorsque la limitation de l'espace est un facteur. Veuillez prendre note que l'endroit où le fil sort du chemisage ne sera pas aussi durable que sur la sonde modèle PR-11, qui possède une jonction de transition en métal et un réducteur de tension à ressort.

Pour des options spéciales, veuillez consulter notre département des ventes pour les prix et les disponibilités.

Les prix des modèles les plus courants sont donnés dans le tableau "Pour commander". Utilisez le "Tableau Constructeur de référence" ci-dessous pour déterminer le prix des autres modèles.

Pour obtenir les caractéristiques complètes de ces produits, consultez les "Liens associés - Produits reliés" sous le "Tableau Constructeur de référence".

loading all models
loading all reviews
Rated 5 out of 5 by from Omega arrived quickly and read accurate when installed. no wiring schematic made connecting a little difficult, but as there is only 3 wires it was easy to figure out
Date published: 2022-02-17
Rated 5 out of 5 by from RTD This is an standard commonly used in the industry for low temperature monitoring. Stable, reliable, efficient and good application instead of a thermocouple. I ordered many of them for our projects.
Date published: 2022-01-20
Rated 5 out of 5 by from RTD Work pretty good. Got the RTD within 2 weeks instead of the 1 month I was told.
Date published: 2021-06-25
Rated 5 out of 5 by from Quality and consistent construction The large number of configurations of these probes is helpful to find one that is just right for the application.
Date published: 2020-12-07
Rated 2 out of 5 by from RTD Bad Ground The RTD is a three wire unit that appears robust and arrived in the configuration that was ordered. However, when it was connected to the digital controller for the oven, the sensor signal was lost each time the oven reached about 120 F. Tracing the issue revealed that one of the ground wires from the RTD had a bad connection. Just touching the wire as it exited the sensor would cause it to loss connection. The wire was not strained during installation given the generous space afforded by the oven. Since my lead wire is only 6' long, I am not so concerned about the added accuracy a 3-wire RTD offers over a 2-wire. So, I placed a jumper on the controller to connect both of the grounds together. If the lead time for ordering a new RTD was not so long, I would have returned this defective unit.
Date published: 2020-08-21
  • y_2024, m_5, d_16, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_13
  • loc_en_CA, sid_PR-10L-3-100-1-4-6, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
loading all QA

The RTD I got have two red leads and one white leads. I also have this RTD connector from Omega (MTP-U-F); the three prongs are labeled cp+, cp-, and ground. What is the correspondence between these two componenets?

Asked by: hyaaq
Thank you for your inquiry. The two red leads go into the cp+ and cp- terminals of the connectors while the white lead goes into the ground terminal
Answered by: Application Engineer MC
Date published: 2023-10-14

What is the difference between your red red white 3 wire rtd and your black black red 3 wire rtd?

Asked by: Anonymous
Thank you for your inquiry. There is no difference in functionality, only color.
Answered by: Application Engineer CB
Date published: 2023-04-26

Any alternative wire sheath can withstand 400C?

Asked by: 91206
Thank you for your inquiry. Unfortunately we don't make a higher temperature wire beyond 250°C.
Answered by: Application Engineer CB
Date published: 2022-10-31

Looking to understand the difference between a 3 and 4 wire RTD Probe. On the 3 wire let's assume the 2 wires of the same color are the positive/negative, and the other color is the shield ground. So on the 4 wire, is the extra wire a safety ground?

Asked by: CGrizzle
Thank you for your inquiry. Please refer to this video link: https://youtu.be/VBMIOZcUz88?si=XnFKYFcn_HiIYVrI
Answered by: Application Engineer CB
Date published: 2024-05-14

How long is the sensor portion compared to the wire length?

Asked by: questioning_user
Thank you for your inquiry. The sensor is placed right at the tip of the probe.
Answered by: Application Engineer SP
Date published: 2023-10-02
  • y_2024, m_5, d_16, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_13
  • loc_en_CA, sid_PR-10L-3-100-1-4-6, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 38ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration