text.skipToContent text.skipToNavigation

Sonde à RTD de surface avec design innovateur: À Coller ou à Cimenter<br> <font color = red>Précision Classe A </font>

SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment

C$100.00

Article# SA1-RTD

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$100.00
10-24 C$95.00
25-99 C$90.00
100-499 C$85.00
500-999 C$80.00
1000+ C$75.00

En stock

Délai de livraison (si pas en stock): 7 semaines
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment SA1-RTD SA1-RTD
  • La sonde contient un élément de platine de 100 ohms de précision Classe A DIN (±0.06 ?, ±0.15°C à 0°C), alpha = 0.00385 ?/?/°C
  • Adhésif au silicone facile à installer conçu pour résister jusqu'à 260°C (500°F)
  • L'adhésif peut être réappliqué
  • Gamme de température: -73°C à 260°C (-100 à 500°F) en continu, 290°C (554°F) pour de courtes périodes lorsqu'installé avec le ciment OMEGABOND™
  • Construction standard à 3 fils dénudés (connecteur optionnel). Code de couleur : noir/noir/rouge
  • Construction optionnelle à 4 fils. Code de couleur : noir/noir/rouge/rouge
  • Stockés en longueurs de 40 pouces (1 m). Également disponible en longueur de 80 pouces (2 m), 120 pouces (3 m) et en longueur de fils sur mesure.
  • Autres résistances/précisions disponibles sur demande
  • Surtressage en acier inoxyable disponible pour réduire les bruits électriques et pour protéger le câble d'extension de l'abrasion

SA1-RTD Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.

Number of Wires
Cable Insulation
Termination Connection Type
Cable Length
Category
Process Temperature Range
Sensor Application
Nominal Resistance
Accuracy
Mounting Style
Maximum Temperature Measurement
Minimum Temperature Measurement


Description

Spécifications
Température minimale/maximale:
-73°C (-100°F) à 260°C (500°F) en continu, 290°C (554°F) pour de courtes périodes (lorsque cimenté)
Elément sensitif: 100 ? à 0°C, coefficient de température de 0,00385 ?/?/°C (IEC60751)
Précision: ±0,06? à 0°C (Classe A DIN)
Stabilité: Moins de 0,2°C de dérivation/an
Temps de réponse: Moins de 1 s (63% temps de réponse lors de l'immersion dans l'eau), moins de 2 s sur une plaque chauffante
Effet d'auto-échauffement: 2,5 mW/°C
Fil de liaison standard: 3 fils de cuivre plaqué nickel de 40 pouces (1 m) de long, de jauge 26 AWG avec isolation en PFA avec code de couleur noir/noir/rouge.

Le capteur de température à RTD Pt100 à montage en surface SA1-RTD se fixe sur des surfaces plates ou courbées et peut être appliqué facilement sur la plupart des surfaces propres et sèches. Ces senseurs ont une précision de Classe A (Voir tableau Tolérances standards IEC 751 Classe A/B , ci-dessous). Basé sur un élément Pt100 à couche mince de 2 x 2 x 0,8 mm et fourni avec des câbles à 3 fils standard (connecteur en option), ils peuvent être fabriqués sur mesure afin de pouvoir les utiliser dans une multitude d'applications.

Le design mince du SA1-RTD minimise les effets d'avoir un capteur installé sur la surface de l'objet. Avec un temps de réponse très rapide, le SA1-RTD répondra rapidement à toute variation de température afin de fournir une mesure fiable dans un délai le plus court possible. Utilisez le SA1-RTD pour surveiller la température des microprocesseurs, des dissipateurs de chaleur et pour les températures environnementales à l'intérieur d'appareils électroniques; pour vérifier les températures des tuyaux et des conduits; pour contrôler la chaleur du moteur et transformateur; pour tester les capacités d'isolation; et pour vérifier les autres applications dans lesquelles les températures de surface et/ou gradients doivent être surveillées ou controlées.

Pour vos projets d'automatisation ayant besoin de sondes à RTD requérant un interface avec des PLC's (avec entrées à RTD), des IHM's ou des Contrôleurs/Moteurs pas à pas, visitez OMEGAMATION.COM pour combler vos besoins en produits d'automatisation. Des boîtiers NEMA, des RTD's, des blocs de terminaisons standards et des fils de raccordement en plus des produits contrôlés pneumatiquement incluant des actuateurs, des raccords de connexion, des vannes et des tuyaux flexibles sont en inventaire.




Également disponible avec un surtressage en acier inoxydable
Pour les application où le bruit électrique est présent ou pour les endroits où le câble d'extension passe près d'extrémités coupantes, l'option de surtressage en acier inoxydable "-SB" permettra de réduire considérablement le bruit et protégera le filage. Ajoutez "-SB" à la fin du numéro de pièce indiqué dans le tableau sur les feuilles de spécifications, et ajoutez 2$U.S./pied (6$U.S. /mètre).

loading all models
loading all reviews
Rated 5 out of 5 by from BOM sensor I ordered temperature sensors to monitor solar panels temperature to analyze performance
Date published: 2016-10-23
Rated 4 out of 5 by from Works great Does exactly what it says it does. Installed easily with epoxy from omega. Plenty accurate for our purposes. Cost effective
Date published: 2017-02-28
Rated 5 out of 5 by from Easy to use RTD with self adhesive Easy to use RTD with self adhesive that can conform to the curved surface of piping.
Date published: 2021-05-06
Rated 5 out of 5 by from Excellent Turn-Around Time Amazed at the extremely short-lead time. It arrived prior to the expected arrival time, and kept the project it was needed for Operationally Ready prior to the Completion Timeline.
Date published: 2021-03-24
Rated 1 out of 5 by from Didn't stick well The adhesive melted well before the stated temperature limit
Date published: 2020-04-17
Rated 5 out of 5 by from As Advertised I have used these on several projects, and the work exactly as advertised. I have not had a problem with any of them.
Date published: 2018-01-25
  • y_2022, m_5, d_23, h_21
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.27
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_en_CA, sid_SA1-RTD, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 1ms
  • REVIEWS, PRODUCT
loading all QA

I'm interested in purchasing one of these, but I can't find information regarding acceptable current bounds; can you give me an estimate on minimum required current to operate this sensor, and maximum not to toast it?

Asked by: EAML
Hi EAML, Normal excitation current is 1mA or less. Minimum current level is determined by the instrument being used. Higher levels will cause readings to be affected by self heating errors. We do not have established current level which can cause burnout. Best regards OMEGA
Answered by: NorwalkAE
Date published: 2020-06-09

What are the color codes of the 3 wires?

Asked by: tackoo
Does anyone know what the colors correspond to? Thanks.
Answered by: Borzman
Date published: 2021-10-18

It says, 'back can be reapplied' in the product description. Is there back adhesive material that can be used for this RTD?

Asked by: RTD_engineer
The SA1-RTD if carefully removed can be reattached but each time will lose some of its adherent properties. Sometimes when it no longer sticks a piece of Kapton tape can be laid over the top to hold it in place,
Answered by: ANENG
Date published: 2020-04-15

What is the best method to cut the PFA wire covering to get access to more of the leads?

Asked by: Brad Nickname in Use
Omega sells the TW-6 which is designed to remove the outer insulation of wires with ease. You can enter TW-6 in the search box on Omega's web page for further details.
Answered by: Applications Engineer AB
Date published: 2020-05-11

For a DAQ device with EX0, RTD+, RTD-, and COM ports (such as NI 9217), which wire go to which port? (For both 3-wire and 4-wire RTDs)

Asked by: tackoo
Thank you for your inquiry. COM &amp; RTD- should have 1 Black Wire Each. EX0 &amp; RTD+ should have 1 Red Wire Each.
Answered by: CB Engineer
Date published: 2020-09-09

Is the self adhesive backing easy to remove after a month or so of use? We need to monitor temperatures on piping for a month or so, then the sensors will need to be removed. Working temperature while monitoring will be around 90 degrees c

Asked by: Mikecandu
Thank you for your inquiry. The entire assembly can be removed carefully, but the self-adhesive properties will be lost.
Answered by: Application Engineer JB
Date published: 2019-11-19

What are the dimensions (width and thickess) of the cable?

Asked by: Dave Z
Thank you for your inquiry Dave Z. The wire gauge of this sensor is 26 AWG. It has a nominal size of 0.060&quot; x 0.064&quot;.
Answered by: Application Engineer MC
Date published: 2022-04-29

Does anybody have a recommendation for temperature sensing device to connect to this sensor? One that could connect to a computer, ideally.

Asked by: ap0720
You may want to consider the SA1-RTD-80 with the HH804U handheld meter along with the software HH800-SW (windows software and USB cable) which allows for real time data logging to a PC. For extensive data logging a DC power jack is available HH804U Meter $173.88 each in stock Comes complete with HH804-CONNECTOR (one per channel), protective rubber boot, NIST certificate (no points), 4 &ldquo;AAA&rdquo; batteries, and operator&rsquo;s manual. https://www.omega.com/en-us/sensors-and-sensing-equipment/temperature/thermometers/p/HH804-805 HH800-SW $23.18 in stock Windows software and USB cable (USB models only) https://www.omega.com/en-us/sensors-and-sensing-equipment/temperature/thermometers/p/HH800-SW HH800-ADAPTOR $20.09 each in stock https://www.omega.com/en-us/sensors-and-sensing-equipment/temperature/hygrothermometers/p/HH800-ADAPTOR If a thermocouple can be considered in place of a RTD , for example the SA1-K-72- SRTC is a good option. We offer the Thermocouple Data logger with USB interface the OM-EL-USB-TC which accepts a J, K or T type thermocouple. This plugs directly into a USB Port &ndash; No USB cable is required https://www.omega.com/en-us/control-and-monitoring-devices/data-loggers/p/OM-EL-USB-TC-Series and the specifications sheet is: https://br.omega.com/omegaFiles/das/pdf/OM-EL-USB-TC.pdf Thank you for your question.
Answered by: Application Engineer
Date published: 2022-02-07
  • y_2022, m_5, d_23, h_21CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.27
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_8
  • loc_en_CA, sid_SA1-RTD, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • QUESTIONS, PRODUCT
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
C$139.00
0 In Stock
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
C$151.00
0 In Stock
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
C$167.00
0 In Stock
fr-CA
fr
Enregistrer la configuration