Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

Sonde à RTD de surface avec design innovateur: À Coller ou à Cimenter<br> <font color = red>Précision Classe A </font>

SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment

C$135.18

Article# SA1-RTD

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$135.18
10-24 C$128.42
25-99 C$121.66
100-499 C$114.90
500-999 C$108.14
1000+ C$101.39

En stock

Délai de livraison (si pas en stock): 6 semaines
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment SA1-RTD SA1-RTD
  • La sonde contient un élément de platine de 100 ohms de précision Classe A DIN (±0.06 ?, ±0.15°C à 0°C), alpha = 0.00385 ?/?/°C
  • Adhésif au silicone facile à installer conçu pour résister jusqu'à 260°C (500°F)
  • L'adhésif peut être réappliqué
  • Gamme de température: -73°C à 260°C (-100 à 500°F) en continu, 290°C (554°F) pour de courtes périodes lorsqu'installé avec le ciment OMEGABOND™
  • Construction standard à 3 fils dénudés (connecteur optionnel). Code de couleur : noir/noir/rouge
  • Construction optionnelle à 4 fils. Code de couleur : noir/noir/rouge/rouge
  • Stockés en longueurs de 40 pouces (1 m). Également disponible en longueur de 80 pouces (2 m), 120 pouces (3 m) et en longueur de fils sur mesure.
  • Autres résistances/précisions disponibles sur demande
  • Surtressage en acier inoxyable disponible pour réduire les bruits électriques et pour protéger le câble d'extension de l'abrasion

SA1-RTD Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.

Number Of Wires
Cable Insulation
Termination Connection Type
Cable Length
Category
Process Temperature Range
Sensor Application
Nominal Resistance
Accuracy
Mounting Style
Maximum Temperature Measurement
Minimum Temperature Measurement


Description

Spécifications
Température minimale/maximale:
-73°C (-100°F) à 260°C (500°F) en continu, 290°C (554°F) pour de courtes périodes (lorsque cimenté)
Elément sensitif: 100 ? à 0°C, coefficient de température de 0,00385 ?/?/°C (IEC60751)
Précision: ±0,06? à 0°C (Classe A DIN)
Stabilité: Moins de 0,2°C de dérivation/an
Temps de réponse: Moins de 1 s (63% temps de réponse lors de l'immersion dans l'eau), moins de 2 s sur une plaque chauffante
Effet d'auto-échauffement: 2,5 mW/°C
Fil de liaison standard: 3 fils de cuivre plaqué nickel de 40 pouces (1 m) de long, de jauge 26 AWG avec isolation en PFA avec code de couleur noir/noir/rouge.

Le capteur de température à RTD Pt100 à montage en surface SA1-RTD se fixe sur des surfaces plates ou courbées et peut être appliqué facilement sur la plupart des surfaces propres et sèches. Ces senseurs ont une précision de Classe A (Voir tableau Tolérances standards IEC 751 Classe A/B , ci-dessous). Basé sur un élément Pt100 à couche mince de 2 x 2 x 0,8 mm et fourni avec des câbles à 3 fils standard (connecteur en option), ils peuvent être fabriqués sur mesure afin de pouvoir les utiliser dans une multitude d'applications.

Le design mince du SA1-RTD minimise les effets d'avoir un capteur installé sur la surface de l'objet. Avec un temps de réponse très rapide, le SA1-RTD répondra rapidement à toute variation de température afin de fournir une mesure fiable dans un délai le plus court possible. Utilisez le SA1-RTD pour surveiller la température des microprocesseurs, des dissipateurs de chaleur et pour les températures environnementales à l'intérieur d'appareils électroniques; pour vérifier les températures des tuyaux et des conduits; pour contrôler la chaleur du moteur et transformateur; pour tester les capacités d'isolation; et pour vérifier les autres applications dans lesquelles les températures de surface et/ou gradients doivent être surveillées ou controlées.

Pour vos projets d'automatisation ayant besoin de sondes à RTD requérant un interface avec des PLC's (avec entrées à RTD), des IHM's ou des Contrôleurs/Moteurs pas à pas, visitez OMEGAMATION.COM pour combler vos besoins en produits d'automatisation. Des boîtiers NEMA, des RTD's, des blocs de terminaisons standards et des fils de raccordement en plus des produits contrôlés pneumatiquement incluant des actuateurs, des raccords de connexion, des vannes et des tuyaux flexibles sont en inventaire.




Également disponible avec un surtressage en acier inoxydable
Pour les application où le bruit électrique est présent ou pour les endroits où le câble d'extension passe près d'extrémités coupantes, l'option de surtressage en acier inoxydable "-SB" permettra de réduire considérablement le bruit et protégera le filage. Ajoutez "-SB" à la fin du numéro de pièce indiqué dans le tableau sur les feuilles de spécifications, et ajoutez 2$U.S./pied (6$U.S. /mètre).

loading all models
loading all reviews
Rated 5 out of 5 by from BOM sensor I ordered temperature sensors to monitor solar panels temperature to analyze performance
Date published: 2016-10-23
Rated 4 out of 5 by from Works great Does exactly what it says it does. Installed easily with epoxy from omega. Plenty accurate for our purposes. Cost effective
Date published: 2017-02-28
Rated 5 out of 5 by from Great Purchase good quality product. customer service is always there to help
Date published: 2024-02-15
Rated 5 out of 5 by from RTD Sensor RTD's worked as we expected and were easy to order.
Date published: 2023-10-16
Rated 5 out of 5 by from Good customer service and quality product. Worked as expected, purchase was easy and customer service rep was very helpful and answered all my questions before order.
Date published: 2023-07-18
Rated 5 out of 5 by from Communication There were some issues with raw materials and was never communicated. I had to expedite the order to find out that the order has been delayed. However, Omega was very helpful to escalate the issue and sort out the raw material issue in good time.
Date published: 2023-05-26
Rated 5 out of 5 by from Order Thanks for the fast delivery! Nice quality,and best support!
Date published: 2023-05-26
Rated 5 out of 5 by from very accurate with the right controller,buy a cple these surface probes work very well, the adhesive sticks good
Date published: 2023-03-23
  • y_2024, m_3, d_27, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_13
  • loc_en_CA, sid_SA1-RTD, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
loading all QA

I'm interested in purchasing one of these, but I can't find information regarding acceptable current bounds; can you give me an estimate on minimum required current to operate this sensor, and maximum not to toast it?

Asked by: EAML
Hi EAML, Normal excitation current is 1mA or less. Minimum current level is determined by the instrument being used. Higher levels will cause readings to be affected by self heating errors. We do not have established current level which can cause burnout. Best regards OMEGA
Answered by: NorwalkAE
Date published: 2020-06-09

It says, 'back can be reapplied' in the product description. Is there back adhesive material that can be used for this RTD?

Asked by: RTD_engineer
The SA1-RTD if carefully removed can be reattached but each time will lose some of its adherent properties. Sometimes when it no longer sticks a piece of Kapton tape can be laid over the top to hold it in place,
Answered by: ANENG
Date published: 2020-04-15

Hi, could you please send me or link here a &quot;Resistance vs Temperature table&quot; for the SA1-RTD (3 wires)? Regards.

Asked by: Sborzy
Thank you for your inquiry Sborzy. Please review the following link for the table: https://assets.omega.com/tech-ref-legacy-pdfs/z252-254.pdf
Answered by: Application Engineer MC
Date published: 2022-08-25

What is the best method to cut the PFA wire covering to get access to more of the leads?

Asked by: Brad Nickname in Use
Omega sells the TW-6 which is designed to remove the outer insulation of wires with ease. You can enter TW-6 in the search box on Omega's web page for further details.
Answered by: ApplicationsEngineerANB
Date published: 2020-05-11

In the spec sheet, there are tolerances listed for down to -200&deg;C. My application requires use down to -100&deg;C; is -73&deg;C the cutoff for optimal precision, or does the sensor stop working below this minimum temperature rating?

Asked by: emj2
These RTD probes will work down to -100C and lower but the adhesive is not effective below-73C so the should be mechanically secured.
Answered by: ApplicationsEngineerANB
Date published: 2024-02-23

What is the recommended method of calibrating these sensors?

Asked by: Pharma_L
Thank for your inquiry. Surface Wire Sensor when calibrated, is done before the adhesive pad is attached. Not after. We recommend purchase calibrated sensors from OMEGA.
Answered by: Application Engineer CB
Date published: 2023-07-26

How to calculate temperature error for adhesive film between RTD and surface? How much error should I expect from the adhesive if my surface temperature is 100C and air temperature is 25C?

Asked by: TEBrian
Hi TEBrian, Thank you for the inquiry. Please forward this question to TEMP@OMEGA.COM. Best regards, OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-08-02

The data sheet mentions installation using Omegabond thermal epoxy. What is the correct/recommended process for epoxy install? Does the polyimide tape get completely removed, and then epoxy the RTD on? Seems like tape on epoxy would not create a good bond

Asked by: RPeebs
Thank you for your inquiry RPeebs. You will need to use thermal conductive epoxy that way you don't block the heat from coming into contact with the probe. The pad should not affect the temperature measurement if you decide to use epoxy in conjunction with the adhesive pad.
Answered by: Application Engineer MC
Date published: 2022-08-25
  • y_2024, m_3, d_27, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_16
  • loc_en_CA, sid_SA1-RTD, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 11ms
  • QUESTIONS, PRODUCT
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
C$198.43
0 In Stock
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
C$205.07
3 In Stock
SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
C$234.97
0 In Stock
fr-CA
fr
Enregistrer la configuration