text.skipToContent text.skipToNavigation
Alerte: Veuillez prendre note que tous les bureaux et centres d’expéditions situés aux États-Unis seront fermés les 26 et 27 novembre 2020 pour Thanksgiving.

Fine Diameter Thermocouple Wire

C$100.00

Article# SPCH-005-500

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$100.00
5-9 C$95.00
10-24 C$90.00
25-49 C$85.00
50-99 C$80.00
100+ C$75.00

En stock

Délai de livraison (si pas en stock): 6 semaines

Fine Diameter Thermocouple Wire SPCH-005-500 SPCH-005-500
Fine Diameter Thermocouple Wire is rated 4.7 out of 5 by 3.
  • y_2020, m_11, d_26, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_SPCH-005-500, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 14ms
  • REVIEWS, PRODUCT
  • Disponible - expédition immédiate
  • Diamètres des fils de 0,27mm à 3,26 mm
  • Bobines de 15, 30, 150, 300 mètres

Modifier les options

Voir tous les modèles

Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Category
Thermocouple Type
Process Temperature Range
Calibre du fil
Type de fil
Matched Pair
Longueur de câble
Additional Feature


Spécifications du produit

Description

Pour répondre aux besoins scientifiques et industriels de fils de thermocouple de qualité à des prix raisonnables, OMEGA propose des matériaux pour thermocouple dans une gamme variée de diamètres de fils. Le fil est fourni non isolé sur des bobines plastiques standard en longueur continue de 15 m.

Les diamètres vont de 0,012 à 3,264 mm. Le fil est fourni à l'unité ou en lot de deux bobines appairées pour correspondre aux limites de précision standard et en forme d'unités simples ou en paires assorties pour atteindre les limites standard d'erreurs. D'autres diamètres de fils, longueurs et quantités sont également disponibles sur demande.

EXEMPLES DE MODELES COURANTS CI-DESSOUS. VEUILLEZ UTILISER LE TABLEAU CONSTRUCTEUR DE REFERENCE POUR TROUVER LES MODELES SPECIFIQUES QUI SONT DISPONIBLES.

Rated 4 out of 5 by from Met specifications Pursued copper wire as closest option to model HO scale fence line. May be too fragile to use and tend to curl!!
Date published: 2018-02-04
Rated 5 out of 5 by from Test Wire Bought for testing and worked great, needed ASAP and delivery was on time
Date published: 2017-03-27
Rated 5 out of 5 by from Normal high standard. There is nothing new with this order. There was the same high standard of service and product that I have received with hundreds of orders over 50 years.
Date published: 2016-07-11
  • y_2020, m_11, d_26, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_SPCH-005-500, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 1ms
  • REVIEWS, PRODUCT

I want to use J thermocouple wire without a probe (by twisting the ends of the stripped wires together) to measure the temperature of a curing polyurethane elastomer. I have been told that method is not valid. Is it? Thanks.

Asked by: Pam09
Twisting the wires does create a Thermocouple junction and senses at the point were the two wires first touch each other. This is a crude way to do this and the accuracy would not be truly known and should only be used in applications that have a very loose accuracy tolerance.
Answered by: ANB ENG
Date published: 2020-08-08

How best to connect a fine gauge K-type thermocouple wire (say 40 AWG) to a DAQ box which has a screw pressure contact. Is there a crimp you recommend

Asked by: Anonymous
It is best to call our engineers to review possible options.
Answered by: NJENG
Date published: 2020-02-12
  • y_2020, m_11, d_26, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_SPCH-005-500, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 2ms
  • QUESTIONS, PRODUCT

fr-CA
fr
Enregistrer la configuration