FLEXIBLE SEALED PFA RTD SENSOR, ROHS

HERMETICALLY SEALED RTD PRODE

C$135.82

Article# HSRTD-3-100-A-3M-HH804-CONN

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$135.82
10-24 C$129.03
25-99 C$122.24
100-499 C$115.45
500-999 C$108.66
1000+ C$101.87

En stock

Délai de livraison (si pas en stock): 7 semaines
HERMETICALLY SEALED RTD PRODE HSRTD-3-100-A-3M-HH804-CONN HSRTD-3-100-A-3M-HH804-CONN
  • La sonde contient un élément de platine de 100 ohms à couche mince de précision Classe "A" ou "B" DIN standard. D'autres résistances et classes disponibles
  • Scellé contre l'humidité et la corrosion
  • Câble isolé en PFA
  • Gamme de température : -60 à 260 °C
  • Configuration standard à 4 fils
  • Embout de la sonde à RTD scellé hermétiquement
  • Temps de réponse : 3,75 secondes max dans l'eau circulant à 3 pieds par seconde (63%)

HSRTD-3-100-A-3M-HH804-CONN Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Nominal Resistance
Accuracy
Number of Wires
Termination Connection Type
Cable Length
Color Code Standard
Additional Feature 2
Category
Thermocouple Type
Process Temperature Unit
Process Temperature Min
Process Temperature Max
Process Temperature Range
Junction Type
Cable Insulation
Wire Gauge
Pack Size


Description

Les sondes flexibles de température à RTD's de la série HSRTD sont scellées hermétiquement à l'embout afin de fournir une protection continue de la jonction de la mesure de température. Le câble flexible en PFA de la sonde scelle hermétiquement et isole électriquement le petit senseur à RTD ce qui lui permet de pouvoir être utilisé dans une grande variété d'applications. Le procédé unique de fabrication d'OMEGA ne produit pas d'augmentation du diamètre ni de changement de la forme de la pointe de la sonde, permettant son installation dans les endroits où l'espace est limité. Fourni en standard avec terminaison fils dénudé. D'autres connecteurs et d'autres longueurs de câble de raccordement sont également disponibles.

Pour une sonde à thermocouple hermétiquement scellée, voir le modèle HSTC

Pour vos projets d'automatisation ayant besoin de sondes à RTD requérant un interface avec des PLC's (avec entrées à RTD), des IHM's ou des Contrôleurs/Moteurs pas à pas, visitez OMEGAMATION.COM pour combler vos besoins en produits d'automatisation. Des boîtiers NEMA, des RTD's, des blocs de terminaisons standards et des fils de raccordement en plus des produits contrôlés pneumatiquement incluant des actuateurs, des raccords de connexion, des vannes et des tuyaux flexibles sont en inventaire.


loading all models
loading all reviews
Rated 4 out of 5 by from Resistant to magnetic flux change I have probably purchased 30 of these over the last 5 years. They perform much better than bimetallic thermocouples for reading temperature in magnetic induction applications. The durability is good, but not outstanding in harsh environments, especially in steam at temperatures greater than 120°C (thus the purchase of 30 over the last 5 years). Their response is faster than metal clad RTDs. The rapid response allows for more contained PID controll. It would be wonderful if Omega made a steam-tolerant packing gland for the RTD where the RTD tip was not in contact with a metal (as is the case in a thermowell).
Date published: 2016-07-01
Rated 5 out of 5 by from Durable and easy to use I use these to measure the temperature on the backside of PV modules. The RTDs are easy to use and they are very durable. The pre-tinned wire leads make installation very easy.
Date published: 2020-09-14
  • y_2024, m_3, d_27, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_HSRTD-3-100-A-3M-HH804-CONN, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
loading all QA

Could this RTD sensor measure at temperature for -80°C? I mean would it damage the sensor at -80°C? Let say if I gonna purchase & send to calibration lab for -80°C calibration and obtain the correction factor for this particular temperature to use this.

Asked by: CL Lee
Hi CL Lee, Thank you for the inquiry. The materials are verified to -60 C. I would suggest to test at your target temps for a period of time before investing in calibration for offsets. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-05-16

What is the self-heating coefficient of the 1000 ohm varieties? Also, does the excitation current of the CN32PT readouts change with the 100 ohm vs 1000 ohm RTDs?

Asked by: benjfitz
Thank you for your inquiry benjfitz. The excitation current for 100 ohm or 1000 ohm RTD is 1 mA. The maximum the excitation current can be is 2 mA. Unfortunately, the self-heating coefficient is not available on our current documentation. Please send an email to temp@omega.com and one of our engineers will assist you in finding this information.
Answered by: Application Engineer MC
Date published: 2022-06-02

What are the physical differences between Class B, Class A, 1/3DIN, and 1/10DIN models?

Asked by: benjfitz
Thank you for your inquiry benjfitz. Due to the complexity of your question, please send an email to temp@omega.com and one of our engineers will assist you in finding this information.
Answered by: Application Engineer MC
Date published: 2022-06-02

What is the self-heating coefficient of the HSRTD Pt100 sensors?

Asked by: ned_pcs
The nominal self heating specification for the probes RTD element would be 0.4K/mw at 0C.
Answered by: ApplicationsEngineerANB
Date published: 2022-04-29

I am looking to see if putting HSRTD-3-100-1/10-5M in coolant to measure its temp variation would be ok? Looking to make sure we don't contaminate or damage the sensor.

Asked by: Winnie
Thank you for your inquiry. The HSRTD is a hermetically sealed RTD sensor for immersion applications. It will work with coolant as long the temperature being measured is within the temperature range.
Answered by: Application Engineer MC
Date published: 2023-06-07
  • y_2024, m_3, d_27, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_HSRTD-3-100-A-3M-HH804-CONN, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 64ms
  • QUESTIONS, PRODUCT
FLEXIBLE SEALED PFA RTD SENSOR
C$124.91
90 In Stock
FLEXIBLE SEALED PFA RTD SENSOR
C$233.23
0 In Stock
FLEXIBLE SEALED PFA RTD SENSOR
C$122.13
7 In Stock
FLEXIBLE SEALED PFA RTD SENSOR
C$198.71
0 In Stock
Accessories
Additional mating connector
C$21.19
97 In Stock
Most Popular Accessories
Handheld, Dual Input, Pt3926, Pt3916 and Pt385 RTD Thermometer, Min/Max/Avg, Rel, Hold functions, Accuracy: ± 0.05%
C$292.66
19 In Stock
1/16 DIN On-Off LCD Temperature Controller
C$370.46
6 In Stock
Miniature 3-Pin Connector
C$7.25
1592 In Stock
Popular Options and Accessories
100 O, 4 wire, Class “A” sensor with 4.5m (180") of cable, stripped leads termination
C$189.25
0 In Stock
100 O, 4 wire, Class “A” sensor with 3m (120") of cable, stripped leads termination
C$143.29
0 In Stock
100 O, 4 wire, Class “A” sensor with 6m (240") of cable, stripped leads termination
C$224.78
0 In Stock
100 O, 4 wire, Class “A” sensor with 7.5m (300") of cable, stripped leads termination
C$291.69
0 In Stock
100 O, 4 wire, Class “B” sensor with 3m (120") of cable, stripped leads termination
C$134.38
0 In Stock
100 O, 4 wire, Class “A” sensor with 1m (40") of cable, stripped leads termination
C$140.22
0 In Stock
100 O, 4 wire, Class “B” sensor with 4.5m (180") of cable, stripped leads termination
C$159.35
3 In Stock
100 O, 4 wire, Class “B” sensor with 2m (80") of cable, stripped leads termination