For a CE compliant alternative please see: RDXL6SD-USB
- SD Card, Real-Time Data Logger
- Input Signals: T/C K, J, T, E, R/S, and RTD Pt100 Ω Measurement (RDXL4SD Only)
- Display All Input Channels Simultaneously
- Data Hold, Record Max and Min Reading
RDXL4SD Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Number of Channels
Category
Input Type
Display Type
Supply Power
Communications Protocol
Features
Description
Les modèles portables RDXL4SD & RDXL12SD sont des thermomètres enregistreurs à affichage rétro-éclairé avec fonctions d’analyse. Ces enregistreurs sont alimentés par piles internes et sont capables d’échantillonner, traiter et afficher les mesures sans connexion PC. Avec leur haute résolution et leur convertisseur analogique-numérique rapide (ADC), les RDXL12SD et RDXL4SD répondent à la majorité des exigences d’enregistrement de données des applications industrielles.Ces enregistreurs en temps réel à carte mémoire SD ont une horloge et un calendrier intégrés. La fréquence d’auto-échantillonnage peut être réglée de 1 à 3600 secondes. L’utilisateur peut aussi enregistrer les données manuellement en réglant la fréquence d’échantillonnage à zéro. Ces enregistreurs sauvegardent les données de température des 4 ou 12 canaux ainsi que l’information temporelle (année, mois, date, minute, seconde) sur la carte mémoire SD. Ces données peuvent être, par la suite, téléchargées sur Excel pour analyse.
Le RDXL4SD a 4 canaux thermocouple ou 2 canaux d’entrée PT100. L’affichage peut être réglé afin de voir les canaux 1 à 4 simultanément ou T1, T2 ou T1-T2.
Le RDXL12SD a 12 canaux d’entrée thermocouple. L’affichage permet de voir jusqu’à 8 canaux en même temps. Un bouton poussoir bascule l’affichage des canaux restants.
Spécifications
Ecran LCD: 52 x 38 mm à rétro-éclairage vert
4 canaux: T1, T2, T3, T4, T1-T2
12 canaux: T1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11 et T12.
Entrées capteurs:
RDXL12SD: Thermocouples de types J, K, T, E, R et S.
RDXL4SD: 4 canaux pour thermocouples de types J, K, T, E, R et S, ou 2 canaux for Pt100 ? (DIN IEC 751)
Résolution: 0,1/1°C ou °F
Fréquence d’échantillonnage: 1 à 3600 secondes
Carte mémoire: type SD 1 à 16 GB
Rappel de mémoire: Valeurs Maxi/Mini
Fréquence d’échantillonnage de l’affichage: environ 1 seconde
Interface: RS232/USB
Arrêt: Arrêt automatique préservant la vie de la pile ou arrêt manuel par bouton poussoir.
Température de fonctionnement: 0 à 50°C
Humidité de fonctionnement: Moins de 85% HR
Alimentation: Piles alcalines ou piles durables AA 1.5V (6 pour le RDXL4SD et 8 pour le RDXL12SD). Adaptateur CA en option
Consommation: Approx. 8 mA sans la fonction enregistrement; 30 mA avec la fonction enregistrement. 14mA de plus pour rétro-éclairage
Poids:
RDXL12SD: 945 g
RDXL4SD: 490 g
Dimensions:
RDXL12SD: 225 H x 125 l x 64 mm P
RDXL4SD: 177 H x 68 l x 45 mm P
Rated 5 out of
5
by
bibc from
Easy to use, intuitive interface.
Used this device to collect a days worth of thermal / temperature data, worked really well.
Date published: 2016-02-01
Rated 5 out of
5
by
NRama from
Great Data logger
Got two of these for temperature profiling of our freezers, very convenient to set up and use these.
This model did not have an AC adapter - which could be handy especially for long term data recording (or redundancy) to prevent data loss due to battery draining out.
Otherwise, this is a great unit for portability and convenience.
Date published: 2018-07-05
Rated 5 out of
5
by
Chris8 from
Very versatile temp data logger
Very versatile temp data logger that can handle different types of thermocouple. Can sample at various times and log onto an SD card and easily be viewed in a spreadsheet.
Date published: 2023-08-21
Rated 4 out of
5
by
jpower from
Nice data logger, easy to use
Purchased for manufacturing operations. Works great and easy to use. It has a 3 week leadtime but on time to commitment.
Date published: 2017-08-22
Rated 5 out of
5
by
RonF from
Indispensible to our work.
We have used Omega thermocouples for over 20 years. We still have some from then that still work.
The data logging capabilities of the RDXL Series is a great value for documenting our work for our customers and in preventing costly failures.
Date published: 2017-03-04
Where can I get a 9V power supply for this unit? I got the unit hot and now the battery compartment is warped.
The AC Adapter for the RDXL4SD is the ADAPTER-SD and is sold as an accessory.
Date published: 2020-04-09
Can this model display max/min for ALL 4 channels simultaneously?
Yes, the meter will display all four channels.
Date published: 2019-11-07
I need thermocouples that can be exposed to direct flame. Which ones would be compatible to this device?
Thank you for your inquiry! You can use bare thermocouple wire rated for the appropriate temperature range to directly measure the temperature of a flame. However, if you plan to measure for an extended duration of time, it would be best to select a thermocouple probe for durability and repeatability of your measurements. Lastly, the thermocouple you choose should have a mini connector to connect into this data logger.
Date published: 2021-05-31
I need to record in liquid nitrogen (-320) do you have any recommendations on probes or if this can record temperatures that low.
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:00PM EST).
Date published: 2024-11-28
Will the data still be logged after starting the REC and then powering off the unit? Or does the display need to stay on for the logging to occur?
The Logger should be left on when in record mode. When in record mode the meter enters into a low power consumption operation until recording is terminated.
Date published: 2024-08-02
RDXL 12 SD do you have a calibration manual???
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:30PM EST).
Date published: 2024-04-11
When recording data does the auto off feature need to be (no) or can it be left in auto off (yes)?
Once in record mode the logger will not turn off until it has the recording ended. So it would ignore the APO setting.
Date published: 2024-08-01
Do I need and if yes, how do I start data output on RS232? (I have the unit connected via USB adapter (UPCB-01?) to computer, but cannot see any activity on a terminal software.)
Hello,
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:00PM EST).
Regards,
Omega Engineering Inc
Date published: 2024-11-27