Numéro de produit | Input Type | Input Ranges | Output Type | Display Type | Supply Voltage Type | Isolation | Programability | FM Approved | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
TC, RTD, Resistance, Pot, mA, V, NTC
|
See Detail Specs
|
mA, V
|
None
|
AC/DC
|
2300 V
|
Pushbutton
|
No
|
Universal
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRSL-SP2_l.jpg?imwidth=150)
The DRSL-SP2 is a repeater/splitter that isolates and converts 1 process input to 2 process outputs. DIP switch selectable ranges. Slim housing, high accuracy (0.05%)
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
mA, V
|
Process
|
0 to 20 mA, 0 to 10 Vdc
|
mA, V (x2)
|
Splitter
|
DC
|
300 V
|
Switch
|
Splitter
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DMD4059_l.jpg?imwidth=150)
The DMD4059 Series converts wheatstone strain bridge sensors, pressure transducers, or load cell signals into process current or voltage. Offered with AC or DC Power.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
mV
|
Bridge, strain, mV
|
0 to 400 mV dc
|
mA, V
|
Process
|
AC
|
1200 V
|
Trim Pot/Switch
|
Adjustable Excitation
|
|
mV
|
Bridge, strain, mV
|
0 to 400 mV dc
|
mA, V
|
Process
|
DC
|
1200 V
|
Trim Pot/Switch
|
Adjustable Excitation
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRSL-LPI_Series_l.jpg?imwidth=150)
The DRSL-LPI Series Conditioners are 1 or 2 channel analog input loop powered isolators. 1:1 signal ratio, low input voltage drop, slim housing.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
mA
|
Process
|
0 to 20 mA
|
mA
|
Process
|
Loop
|
300 V
|
Switch
|
2-Channel
|
|
mA
|
Process
|
0 to 20 mA
|
mA
|
Process
|
Loop
|
300 V
|
Switch
|
1-Channel
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/CCT_l.jpg?imwidth=150)
CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
Frequency
|
Frequency
|
Min 0 to 125 Hz, Max 0 to 225 Hz
|
mA, V
|
Process
|
AC
|
2000 V
|
Trim Pot/Jumpers
|
Not Applicable
|
|
mA, V
|
Process
|
0 to 50 mA dc, 18 Vdc max
|
mA, V
|
Process
|
Loop
|
2000 V
|
Trim Pot/Jumpers
|
Not Applicable
|
|
DC Current
|
0 to 5 mA, 0 to 50 mA
|
mA, V
|
AC
|
2000 V
|
Trim Pot/Jumpers
|
|||
|
V
|
0 to 0.1 Vdc, 0 to 1 Vdc, 0 to 10 Vdc, 0 to 100 Vdc, 0 to 650 Vdc
|
mA, V
|
AC
|
2000 V
|
Trim Pot/Jumpers
|
|||
|
V
|
Process
|
0 to 1 Vdc
|
mA, V
|
Process
|
AC
|
2000 V
|
Trim Pot/Jumpers
|
Not Applicable
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRC-4710_4720_l.jpg?imwidth=150)
The DRC-4710 and 4720 are DIN Rail bridge input signal conditioners that accept bridge (strain gage, load cell, or voltage) inputs and have 0-10Vdc or 4-20mA outputs.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mV
|
Bridge, strain, mV
|
0 to 30 mV dc
|
V
|
Process
|
DC
|
None
|
Switch
|
|
mV
|
Bridge, strain, mV
|
0 to 30 mV dc
|
mA
|
Process
|
DC
|
None
|
Switch
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/TXDIN70_l.jpg?imwidth=150)
The TXDIN70 series provide two channel transmitters or isolators with 4-20 or 0-20 mA output. Programmable input types with TXDIN70-DISPLAY accessory (sold separately)
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
TC, RTD, mV
|
Temperature
|
See Detail Specs
|
mA
|
Process
|
AC
|
2300 V
|
Display Programmer
|
|
TC, RTD, mV
|
Temperature
|
See Detail Specs
|
mA
|
Process
|
DC
|
2300 V
|
Display Programmer
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DMD4380_l.jpg?imwidth=150)
The DIN Rail DMD4380 Series converts, amplifies, filters and optically isolates mA or V input signals to process current or voltage outputs. Loop powered w/ 1200V isolation.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mA, V
|
Process
|
0 to 50 Vdc, 0 to 50 mA dc
|
mA, V
|
Process
|
AC
|
1200 V
|
Trim Pot/Switch
|
|
mA, V
|
Process
|
0 to 50 Vdc, 0 to 50 mA dc
|
mA, V
|
Process
|
DC
|
1200 V
|
Trim Pot/Switch
|
![thumbnail](https://assets.omega.com/original-images/D/DR-I4/DR-I4_450.jpg?imwidth=150)
The LCKD series are Omega's smallest load cells. They are temperature compensated, with ±0.25% linearity and 2mv/V output in capacities from 2.2 lbf to 1,000 lbf.
Numéro de produit | Input Type | Input Ranges | Output Type | Display Type | Supply Voltage Type | Isolation | Programmability | Additional Feature | FM Approved |
---|---|---|---|---|---|---|---|---|---|
|
AC or DC Voltage, Current, or Frequency
|
50 mVAC up to 600 VAC
|
mA, V
|
Front Panel
|
18 to 256V ac/dc isolated
|
3000 V
|
Pushbutton
|
Universal
|
No
|
|
Frequency
|
0/1 Hz up to 0/1 MHz.
|
mA, V
|
Front Panel
|
18 to 265V ac/dc isolated
|
3000 V
|
Pushbutton
|
Universal
|
No
|
|
Strain/Bridge
|
0/5 mV up to 0/80mV
|
mA, V
|
Front Panel
|
18 to 256V ac/dc isolated
|
3000 V
|
Pushbutton
|
Universal
|
No
|
|
TC, RTD, Resistance, Pot, mA, V, NTC
|
See Detail Specs
|
mA, V
|
Front Panel
|
18 to 256V ac/dc isolated
|
3000 V
|
Pushbutton
|
Universal
|
No
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRSL-DC2_l.jpg?imwidth=150)
The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.05% accuracy
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
mA, V
|
Process
|
0 to 20 mA, 0 to 10 Vdc
|
mA, V
|
Process
|
DC
|
300 V
|
Switch
|
0.05% Accuracy of Span
|
|
mA
|
Process
|
0 to 20 mA
|
mA
|
Process
|
DC
|
300 V
|
Switch
|
Repeater, 0.05% Accuracy of Span
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRSL-RTD_Series_l.jpg?imwidth=150)
The DRSL-RTD is either isolated or non-isolated with 2, 3, or 4-wire Pt100 RTD input. Pre-calibrated temp ranges selectable via DIP switch. Slim housing, high accuracy.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
RTD
|
Temperature
|
-200 to 850°C
|
mA, V
|
Process
|
DC
|
None
|
Switch
|
|
RTD
|
Temperature
|
-200 to 850°C
|
mA, V
|
Process
|
DC
|
300 V
|
Switch
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRSL-TC_Series_l.jpg?imwidth=150)
The DRSL-TC Series are isolated or non-isolated thermocouple input signal conditioners. Accepts Type J and Type K TC's. DIP switch selectable ranges, slim housing.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
TC
|
Temperature
|
J -100 to 1200°C, K -180 to 1372°C
|
mA, V
|
Process
|
DC
|
300 V
|
Switch
|
Isolated
|
|
TC
|
Temperature
|
J -100 to 1200°C, K -180 to 1372°C
|
mA, V
|
Process
|
DC
|
None
|
Switch
|
Non-Isolated
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/TXDIN400_l.jpg?imwidth=150)
TXDIN400 series transmitters accept thermocouple or RTD input (TX401) or process voltage, current, or resistance (TX402). Configurable via RFID with TX400-RFID accessory.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
TC, RTD, mV
|
Temperature
|
See Detail Specs
|
mA
|
Process
|
Loop
|
1000 V
|
RFID Programmer
|
|
Resistance, mA, mV
|
Process
|
0 to 4K Ohm, 0 to 20 mA, 0 to 10 Vdc
|
mA
|
Process
|
Loop
|
1000 V
|
RFID Programmer
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/TXDIN1600S_l.jpg?imwidth=150)
TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mV
|
Bridge, strain, mV
|
-38 to 38 mV dc
|
mA, V
|
Process
|
DC
|
500 V
|
Pushbutton/Software
|
![thumbnail](https://assets.omega.com/images/flatline-images/DRF-LC.jpg?imwidth=150)
The DRF-LC Series Conditioners are load cell input with 0-10V or 4-20mA output. For load cells with 1, 2, or 3 mV/V output. Full scale at 10, 20, or 30mV. Pre-tare jumpers
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|
|
mV
|
Bridge, strain, mV
|
0 to 10 mV dc
|
V
|
Process
|
DC
|
3500 V
|
Trim Pot
|
|
mV
|
Bridge, strain, mV
|
0 to 20 mV dc
|
V
|
Process
|
DC
|
3500 V
|
Trim Pot
|
|
mV
|
Bridge, strain, mV
|
0 to 30 mV dc
|
V
|
Process
|
DC
|
3500 V
|
Trim Pot
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRSL-U_l.jpg?imwidth=150)
The DRSL-U is a universal input conditioner that accepts thermocouple, RTD, resistance, potentiometer, voltage or current input. Configured w/ DRSL-DISPLAY programmer.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programmable | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
TC, RTD, Resistance, Pot, mA, V
|
Universal
|
See Detail Specs
|
mA, V
|
Process
|
DC
|
300 V
|
Requires DRSL-DISPLAY and DRSL-ADAPTOR
|
Universal
|
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
None
|
None
|
Requires DRSL-DISPLAY and DRSL-ADAPTOR
|
Docking Station for Programming DRSL-U
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRST-FR_l.jpg?imwidth=150)
The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Display Type | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|
|
Frequency
|
Frequency
|
0 to 20 KHz
|
mA, V
|
Process
|
None
|
AC/DC
|
3750 V
|
USB Communication Kit
|
Relay Outputs
|
![thumbnail](https://assets.omega.com/images/flatline-images/DR-IO.jpg?imwidth=150)
DR-IO Conditioners convert TTL levels to PLC levels and vice versa. Logic levels switch high level AC/DC circuits and vice versa. Wide logic voltage range and Low profile.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Supply Voltage Type | Isolation | Programability | Additional Feature |
---|---|---|---|---|---|---|---|---|---|
|
TTL
|
Open Collector
|
4 to 28 Vdc
|
5 to 60 Vdc
|
DC Voltage
|
Self-Powered
|
4000 V
|
None
|
Low Leakage
|
|
TTL
|
0 To 280 Vac
|
0 To 280 Vac
|
Self-Powered
|
4000 V
|
None
|
Logic Negative
|
||
|
TTL
|
4 to 28 Vdc
|
Not Applicable
|
Self-Powered
|
4000 V
|
None
|
Logic Positive
|
||
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/TXDIN101_l.jpg?imwidth=150)
TXDIN101 has thermocouple, RTD, and mV input with 4-20mA output. LED display, configuration TX69-CABLE sold separately required to program via PC.
Numéro de produit | Input Type | Input Ranges | Output Type | Display Type |
---|---|---|---|---|
|
Universal (TC, RTD, mV)
|
See Detail Specs
|
mA
|
LED
|
![thumbnail](https://assets.omega.com/images/communication-and-connectivity/signal-conditioners-and-transmitters/signal-conditioners/DRST-AC_l.jpg?imwidth=150)
The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.
Numéro de produit | Input Type | Input Class | Input Ranges | Output Type | Output Class | Display Type | Supply Voltage Type | Isolation | Programability |
---|---|---|---|---|---|---|---|---|---|
|
AC Current/Voltage
|
AC Current/Voltage
|
0 to 5 A, 0 to 300 Vac
|
mA, V
|
Process
|
Programmer
|
AC/DC
|
2300 V
|
Display Programmer
|
Conditionneurs de signal à montage rail DIN
DIN Rail Signal Conditioners are essential for accurate data recording in a wide range of indus...
[+]
![Searching for your items](/_ui/responsive/common/images/spinner.gif)