DIN Rail DC or AC Voltage Input Signal Conditioners
DC and AC Voltage Input Signal Conditioners
- AC/DC Voltage Input Ranges
from 60 mV to 650 V - Accuracy 0.3%
- Response Time for DC Signals, 70 mS
- Response Time for AC Signals, 250 mS
- Over Range Protection for Voltage Inputs
- High Impedance Voltage Inputs
- Galvanic Isolation Between Input, Output and Power
The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 4 to 20 mA, or 0 to 10 Vdc. The DRF series feature a modern housing design, that is easily mounted on standard 35 mm DIN rails. Connections are safely and securely made through pluggable screw terminal connectors, with input and output connections on the opposite sides of the module.
The DRF-VDC and the DRF-VAC voltage signal conditioners accept dc and ac voltages respectively and provide an isolated 0 to 10 Vdc or 4 to 20 mA output. Models are available with three different power options, 24 Vdc, 120 Vac and 240 Vac.
The DRF-VDC and DRF-VAC are ideally suited for industrial applications. All models mount on a standard 35mm DIN rail and provide galvanic isolation between input, output and power up to 3500 Veff (model specific).
Range Code Table for DRF-VDC and DRF-VAC
The DRF-VDC and the DRF-VAC voltage signal conditioners accept dc and ac voltages respectively and provide an isolated 0 to 10 Vdc or 4 to 20 mA output. Models are available with three different power options, 24 Vdc, 120 Vac and 240 Vac.
The DRF-VDC and DRF-VAC are ideally suited for industrial applications. All models mount on a standard 35mm DIN rail and provide galvanic isolation between input, output and power up to 3500 Veff (model specific).
Range Code Table for DRF-VDC and DRF-VAC
Range Code | DRF-VDC Range | DRF-VAC Range |
75MV | 0 to 75 mVdc | 0 to 75 mVac |
150MV | 0 to 150 mVdc | 0 to 150 mVac |
300MV | 0 to 300 mVdc | 0 to 300 mVac |
650MV | 0 to 650 mVdc | 0 to 650 mVac |
1V | 0 to 1 Vdc | 0 to 1 Vac |
7.5V | 0 to 7.5 Vdc | 0 to 7.5 Vac |
15V | 0 to 15 Vdc | 0 to 15 Vac |
65V | 0 to 65 Vdc | 0 to 65 Vac |
300V | 0 to 300 Vdc | 0 to 300 Vac |
650V | 0 to 650 Vdc | 0 to 650 Vac |
SPECIFICATIONS Accuracy: <0.2% full scale Linearity: <0.1% full scale Thermal Drift: 250 ppm/°C typical Thermocouple CJC Drift: 0.1°C/°C Response Time DC Signal Input Models:< 70 mS (90% of signal) AC Signal Input Models: <250 mS (90% of signal) Input Impedance: 1 MΩ for ranges < 1 V, 10 M Ω for ranges > 1 V Over Range Protection: 1000 V for ranges greater than 100 V, 500 V for ranges less than or equal to 100 V Max AC Frequency: 1 KHz Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz, 115 Vac ±10% 50/60 Hz Power Consumption: <3.8 VA | Output: 4 to 20 mA and 0 to 10 Vdc Maximum Voltage Output: 11 Vdc approx. Minimum Voltage Output: -1 Vdc approx. Minimum Load Resistance (Voltage): >1 KΩ Maximum Current Output: 22 mA approx. Maximum Current Output: -1.5 mA approx. Maximum Load Resistance (current): >400 Ω Electrical Connections: Plug-in screw terminals Protection: IP-30 MECHANICAL DIMENSIONS Weight: (DC Powered Models): 120 g (4.2 oz) (AC Powered Models): 200 g (7 oz) Dimensions: (DC Powered models): 110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7") (AC Powered models): 110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7") Operating Temperature: 0 to 60°C (32 to 140°F) Storage Temperature: -20 to 70°C (-4 to 158°F) |


RoHS 2015/863 - Voir le certificat
Approuvé CE