PST rejoint DwyerOmega. En savoir plus>
Subminiature Tension and Compression Load Cell, 0.75" Diameter
500 N, ±1.0%, Linearity, 2 mV/V Output, Cable
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$1,100.47 |
10-24 | C$1,045.45 |
25-49 | C$1,023.44 |
50-99 | C$979.42 |
100+ | C$957.41 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- 5-Point NIST Traceable Calibration Provided
- Subminiature Package for Robotic Applications, 0.75' (19 mm) Diameter
- 0-25 to 0-300 lb Ranges Available
- Dual Mounting Studs for Easy Installation
LCM201-500N Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Weight Capacity
Measurement Units
Height
Force Direction
Linearity
Electrical Output (Nominal)
OD
Connection Type
Cable Length
OMEGA’s LC201 Series subminiature load cell is designed for the demanding environment of industrial automation and robotics. With a diameter of only 0.75" (19 mm) and all stainless steel construction, it can fit into small systems and survive harsh environments. The LC201 delivers high accuracy and long term reliability in a subminiature package.
The LC 201 is also available in metric configurations, with ranges from 0-100 to 0-500 N and metric threads. Please see the LCM201 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 2 mV/V nominal
Accuracy: ±1.0% FSO linearity, hysteresis, repeatability combined
5-Point Calibration (in Tension): 0%, 50%, 100%, 50%, 0%
Zero Balance: ±2% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Protection Class: IP54
Thermal Effects:
Zero: 0.018% FSO/°C
Span: 0.018% FSO/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Input Resistance: 360 ? minimum
Output Resistance: 350 ±10 ?
Construction: Stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable with compensation board
The LC 201 is also available in metric configurations, with ranges from 0-100 to 0-500 N and metric threads. Please see the LCM201 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 2 mV/V nominal
Accuracy: ±1.0% FSO linearity, hysteresis, repeatability combined
5-Point Calibration (in Tension): 0%, 50%, 100%, 50%, 0%
Zero Balance: ±2% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Protection Class: IP54
Thermal Effects:
Zero: 0.018% FSO/°C
Span: 0.018% FSO/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Input Resistance: 360 ? minimum
Output Resistance: 350 ±10 ?
Construction: Stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable with compensation board
Rated 5 out of
5
by
Jamil Hamadeh from
Load Cell for Robotic Application
Great customer support, quick order processing. Highly Recommend Omega Products.
Date published: 2024-02-19
Can this be used in a two in parallel configuration? Any considerations with this?
Hello, the load cells has a nominal output of 2 mV/V but please note that they are not interchangeable, meaning both load cells will not put out an exact 2 mV/V at full load. So if you run them in parallel, you will see some deviation in output.
Date published: 2023-10-24
Is there data available regarding the expected life in cycles?
Our load cells have been tested to greater than 100,000 cycles
Date published: 2024-10-08
When I mount this loadcell I have to have pressure on the threaded pieces of the cell ? Otherwise it wont work !!!! or am I missing something ?
Thank you for your inquire
You are correct
The force is to be applied to the threads only do not bottom out or you will get incorrect readings
Date published: 2021-07-09
What would be the maximum load that could be applied to the cell before damage would be induced? For example I have an application where I need accurate results up to 80N but I have intermittent loads up to 180N but I do not need data above 80N.
Thank you for your question?
The LCM201-100N Has a maximum rating of 150n.
So no you can not go to 180n
Date published: 2019-07-15
Is there any way to have a "special" mode in order to operate above 120°C ? I need to perform some measurements at 150°C. Thank in advance,
Yes. We can provide an extended temperature compensation for the LC201/LCM201 Series load cells. By adding a "-TC2" suffix at the end of the part number the compensated temperature range would be increased 180C. You would need to add $125.00 to the base price of the load.
Date published: 2020-03-11
For Item# LC201-100 Subminiature Tension and Compression Load Cell, 0.75 in Diameter what kind of meters are available?
Thank you for your inquiry
We have a large array of meters that will work.
Please contact the engineering group to discuss.
Date published: 2020-03-06
What's the best way to calibrate the LC201-100? We are currently using known weights to do the calibration, but the values we are getting are not making sense.
The correct way to calibrate a load cell is to use known loads. If you getting odd reading it may be the instrumentation you are using to read the signal is setup. Suggest you contact us at 1-800-826-6342 and request Pressure product technical assistance. We will you verify your setup.
Date published: 2024-11-12
I'm confused about the 2 mV/V output spec. For the LC201-300, if I have a 12V excitation and a 100 lb load, what should the output voltage be? Please include the calculation equation. Thanks!
Thank you for your inquiry
The load cell will work up to 15 vdc.
At 12 vdc you will get a 20% higher output the what was on your calibration sheet.
Hope this was helpful?
Date published: 2022-12-05
Accessories
Accessories and Compatible Meters
Ranges available to 500,000 lb by quotation Accessories