PST rejoint DwyerOmega. En savoir plus>
Low Profile Tension and Compression Load Cell
5,000 lbf, ±0.1%, Linearity, 3 mV/V Output, MIL-26482-I 10-6P
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$1,724.03 |
10-24 | C$1,637.83 |
25-49 | C$1,603.35 |
50-99 | C$1,534.39 |
100+ | C$1,499.91 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- 5 Point NIST Traceable Calibration, Certificate Supplied
- 0.25% Interchangeability for Scale Applications
- All Stainless Steel Construction
- Rugged Heavy Duty Design
LCHD-5K Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Weight Capacity
Linearity
Electrical Output (Nominal)
OD
Through hole (ID)/ Threaded hole dimension
Height
Connection Type
Measurement Units
Force Direction
Low profile load cells are basically compression and tension/compression load cells. Mounting holes and female threads provide easy installation. Used frequently in weighing research and in-line force monitoring.
The LCHD is also available in metric configurations, with ranges from 0-2.5 to 0-10,000 kgf and metric threads. Please see the LCMHD for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc (15 V max)
Output (FSO):
25 lb/10 kgf: 2 mV/V ±0.25%
50 lb/20 kgf: 3 mV/V ±0.25%
5-Point Calibration (in Tension): 0%, 50%, 100%, 50%, 0%
Linearity:
25 lb/10 kgf: ±0.20% FSO
50 lb/20 kgf: ±0.10% FSO
Hysteresis:
25 lb/10 kgf: ±0.10% FSO
50 lb/20 kgf: ±0.08% FSO
Repeatability:
25 lb/10 kgf: ±0.1% FSO
50 lb/20 kgf: ±0.03% FSO
Zero Balance: ±1% of FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.0036% FSO/°C
Span: 0.0036% FSO/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Input Resistance: 350 ±10
Output Resistance: 350 ±10
FS Deflection: 0.025 to 0.076 mm (0.001 to 0.003") typical
Construction: 17-4 PH stainless steel
Electrical:
5000 lb/2000 kgf: DT02H-10-6P
>5000 lb/2500 kgf: MS3102E-14S-6P (or equiv.)
Mating Connector (Included):
5000 lb/2000 kgf: PT06F10-6S
>5000 lb/2500 kgf: MS3102E-14S-6S (or equiv.)
Compatible Meters: DP41-S, DP25-S, LDP63000-S
POPULAR OPTIONS(add as suffix)
-5T ±5 Vdc Output (0 to 5 Vdc in either direction), add ranges 5000 lb
-DUAL Dual Bridge, ranges 5000 lb; ranges >5000 lb
-TC1 Extended Temperature Range -50 to 200°F,
-TC2 Extended Temperature Range -50 to 325°F,
-OL Overload Stops - Consult factory
-TEDS Option are available.
Rated 5 out of
5
by
Anonymous from
LCHD-25 load cell
very dependable unit which runs 24/7. small, compact, easy to mount.
Date published: 2020-12-30
What is the maximum allowable torque due to side load on the load cell, while measuring compression load?
It sounds like what you are looking for is the maximum allowable bending moment due to a side load. Although it may vary depending on the load cell capacity most ranges should be able to handle 25% of capacity in inch pounds. For example, a LCHD-2k, with a capacity of 2000 pounds, would be able to withstand a bending moment of 500 inch pounds. I hope this answers your question but if not I would suggest that you call and speak directly with one of the engineers in the Pressure and Strain department.
Date published: 2024-03-09
Where can I find thread information for the tension plates? Or specifically this tension plate LCHD-TP488
We are emailing you a link to the engineering control drawing for the LCHD tension plates. LCHD-TP488 is the 20,000 to 50,000 lb version
Date published: 2023-05-12
Do you sell a device that connects to and digitally reads the output?
Yes, Our IN-USBH will convert the 3 mV/V analog signal from the load cell to a high speed USB output
Date published: 2024-04-25
How to set up LCHD for compression?
Thank you for the question?
Please review some of the articles or videos from the site.
These we have found to be very helpful to understand this subject.
Date published: 2023-04-10
Does Omega offer piezoelectric-style load cells for fatigue loading? I did a search for "piezo" on the Omega web site and found five series of accelerometers, one series of pressure transducers, but no load cells.
Hello, we currently do not offer piezo-electric style load cells, we only offer bonded strain gauge load cells.
Date published: 2023-09-25
What is the electrical rating? I need Explosion proof or equivalent.
The standard LCHD does not have any explosion proof ratings. If you search our website for Intrinsically Safe, Ultra Low Profile Load Cells you will find a FM Intrinsically Safe Rated version on the LCHD load cells
Date published: 2023-05-12
For years I have used an LCHD-15K-5T for fatigue testing to 10K. You state that the load cell's frequency response time is 3 milliseconds, but the load cells can not be used for dynamic load applications. Why not? High speed accuracy or cumulative damage?
Hello, thank you for contacting us. The LCHD is a bonded strain gauge type load cell, where the strain gauges are adhered on the diaphragm. Dynamic loads will cause them to come unbonded and eventually you will see shift in your zero/span balance.
For dynamic loads it will be better to go with piezo electric style load cells
Date published: 2024-03-09
What is the frequency response of the load cell?
Thank you for your inquire.
Even though these load cells can not be used for dynamic application.
They do have a fast response of 3 Milli seconds
Date published: 2024-03-09
Accessories
Accessories & Compatible Meters
Accessories and Compatible Meters
Ranges available to 500,000 lb by quotation Accessories
15 foot 4 wire cable for LCHD load cells in 5 to 5000 pound ranges
C$206.09
0 In Stock
15 foot 6 wire cable for LCHD load cells in 5 to 5000 pound ranges
C$232.19
0 In Stock
15 foot 6 wire cable for LCHD load cells in ranges > 5000 pounds
C$232.19
1 In Stock