Appelez-nous au 1-888-826-6342
Polyimide Flexible Heater with Polyimide Strain Relief
1 in Width, 3 in Length, Self-Adhesive, 5 W/in2
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$78.59 |
5-9 | C$74.66 |
10-24 | C$73.09 |
25-49 | C$69.95 |
50-99 | C$68.37 |
100+ | C$66.80 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- All polyimide strain relief and insulation
- Optional pressure sensitive adhesive models
- Temperature ranges from -57°C (-71°F) to 232°C (450°F)
- Non-magnetic heating element
PLMLV-103/5-P Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Shape
Temperature range
Power Density
Power (watts)
Supply Voltage
Diameter
Width
Length
Pressure senstivie Adhesive (PSA)
Thickness
Heater Material
The PLM-Series polyimide flexible heaters are offered in a variety of sizes and watt densities. These flexible heaters are polyimide insulated with a polyimide strain relief designed to be used in various environments and hard to reach places. They feature a non-magnetic heating element and watt densities of 2.5 W/in2, 5 W/in2 or 10 W/in2.
PLM-Series heaters have a thickness of 0.01 for a low profile wherever they are installed. Self-adhesive options available for easy and simple installation and eliminate the need for clamping. Temperature ranges from -40°C (-40°F) to 149°C (300°F) for self-adhesive models and -57°C (-71°F) to 232°C (450°F) for no adhesive models.
The PLM-Series heaters are made of polyimide for increased flexibility for curved surfaces and chemical resistivity. The thin nature of these heaters makes them ideal for tight spaces and good for applications such as hot plates, airplanes, storage tanks, beakers, trays, drying chambers and more.
- RoHS 2015/863 - Voir le certificat
- Approuvé CE
- UKCA
Can I use this with rolling itself (overlapped it self) ?
Thank you for your inquiry. 'Hotspots' caused by opposing heat transfers when a heater is overlapped with itself will cause it to fail.
Date published: 2023-07-17
Can you tell me the type of metal (copper, other allow) that is used for the heater traces inside? Thank you.
Hi Inflipant,
Thank you for the inquiry. Please forward this request to TEMP@OMEGA.COM
Best regards
OMEGA
Date published: 2022-05-19
The operation voltage is 28V DC, what is the operating current?
Hi Redneck123
Thank you for the inquiry. To calculate current we have a couple steps;
Need the total watts of your heater. Heaters are normally rated in watts/ sqin and voltage.
To calculate total power. Calculate the area of your heater and multiply the area x watts/sqin.
Next use power law to calculate the current. Power = Voltage x Current
From this; Current = Power / voltage
Hope this is helpful.
Best regards
OMEGA
Date published: 2022-02-11
What is the tolerance on heater resistance? Thanks
The Resistance tolerance for the PLMLV series Heaters is nominally +/- 10%.
Date published: 2022-07-12
Is the plm series able to handle outgassing?
Omega does not specify the outgassing on these Heaters though Polyimide has very low levels. The PLM series is generally used in atmosphere applications.
Date published: 2024-01-30
Can 28V DC PLM series heater work fine at 12v DC? at 12 v it can drain more current as compared to 28v, As P=VI.
Hi Moon,
Thank you for the inquiry. The PLM can operate on 12 VDC. But the power rule is also P=V(squared)/ Resistance. If the voltage was cut in half the P value would be a square of the difference ( 1/4)
Best regards
OMEGA
Date published: 2024-01-30
Is it compatible with 24VDC power input? Can I run it with 24VDC?
Thank you for your inquiry. You may use a lower rated voltage but be aware that you will not reach the maximum total wattage rated at 28V.
Date published: 2024-01-30
Can these be cut ?
Hi Rolling123,
Thank you for the inquiry. These cannot be cut.
Best regards
OMEGA
Date published: 2021-12-03