Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web
The PX309 series is versatile, with a selection of outputs and connections to fit most applications. All items feature high stability, low drift, and ±0.25 or ±0.5% accuracy.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 500 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Male
|
Cable
|
-40 to 85 °C (-40 to 185 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 85 °C (-40 to 185 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-40 to 85 °C (-40 to 185 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 85 °C (-40 to 185 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-40 to 85 °C (-40 to 185 °F)
|
Not Applicable
|
The PX409 series, with a high ±0.08% accuracy, are configurable with several standard pressure, output, and connection options. Our configurator offers additional custom options.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5000 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-45 to 115 °C (-49 to 240 °F)
|
Not Applicable
|
|
16 to 32 inHg
|
Barometric
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-45 to 115 °C (-49 to 240 °F)
|
Not Applicable
|
|
16 to 32 inHg
|
Barometric
|
< 0.1%
|
±0.08%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
26 to 32 inHg
|
Barometric
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-45 to 115 °C (-49 to 240 °F)
|
Not Applicable
|
|
26 to 32 inHg
|
Barometric
|
< 0.1%
|
±0.08%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
The PX3005Kseries are 3-A, clean-in-place, with a backlit LCD display, ideal for monitoring pressures in food, beverage, dairy, and pharmaceutical applications
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
-15 to 250 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-3 to 3 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-5 to 5 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-15 to 15 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-15 to 30 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
The PX119 series are compact, rugged, and cost effective with a 4-20 mA output to integrate with a variety of industrial and OEM applications.
Numéro de produit | Pressure Range Unit | Pressure Range Min | Pressure Range Max | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
psi
|
0
|
150
|
0 to 150 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
-40 to 135 °C (-40 to 257 °F)
|
|
psi
|
0
|
1000
|
0 to 1000 psi
|
Absolute
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
-40 to 135 °C (-40 to 257 °F)
|
|
psi
|
0
|
1000
|
0 to 1000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
-40 to 135 °C (-40 to 257 °F)
|
|
psi
|
0
|
3000
|
0 to 3,000 psi
|
Absolute
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
-40 to 135 °C (-40 to 257 °F)
|
|
psi
|
0
|
3000
|
0 to 3,000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
-40 to 135 °C (-40 to 257 °F)
|
This series has excellent long term stability with adjustable zero and span available in several output and connection options.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 200 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 8-4P
|
-48 to 90 °C (-55 to 195 °F)
|
Not Applicable
|
|
1000 psi (68.9 bar)
|
Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-48 to 90 °C (-55 to 195 °F)
|
Not Applicable
|
|
2000 psi (138 bar)
|
Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-48 to 90 °C (-55 to 195 °F)
|
Not Applicable
|
|
3000 psi (207 bar)
|
Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-48 to 90 °C (-55 to 195 °F)
|
Not Applicable
|
|
5000 psi (345 bar)
|
Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-48 to 90 °C (-55 to 195 °F)
|
Not Applicable
|
The PX1004 and PX1009 series can withstand high operating temperatures up to 232°C (450°F) and 343°C (650°F) respectively, with low thermal drift 1%/100 °F.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 100 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Sealed Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
The PX409S series are available with 1½" or 2" sanitary fittings for clean-in-place applications in food processing, beverage or bio/ pharmaceutical applications.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 15 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
2"
|
Tri-Clamp
|
M12
|
-15 to 115 °C (-5 to 240 °F)
|
Not Applicable
|
|
0 to 32 inHg
|
Barometric
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
Cable
|
-15 to 115 °C (-5 to 240 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
Cable
|
-15 to 115 °C (-5 to 240 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1.5"
|
Tri-Clamp
|
Cable
|
-15 to 115 °C (-5 to 240 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Absolute
|
< 0.1%
|
±0.08%
|
Ratiometric mV/V
|
10 mV/V
|
1.5"
|
Tri-Clamp
|
Cable
|
-15 to 115 °C (-5 to 240 °F)
|
Not Applicable
|
MM Series custom transducers allow for over 1-million possible combinations of parameters such as pressure type, range, unit, material, output, accuracy, fitting, temperature compensation range, and electrical termination.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
880 to 1100 mbar
|
Barometric
|
<0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Conduit
|
-6 to 60 °C (20 to 140 °F)
|
Max Thermal Shift ±0.9% Z±0.6%S
|
|
880 to 1100 mbar
|
Barometric
|
<0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Cable
|
-40 to 100°C (-40 to 220 °F)
|
Max Thermal Shift ±0.8% Z±0.3%S
|
|
26 to 32 inHg
|
Barometric
|
<0.1%
|
±0.05%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Conduit
|
-6 to 60 °C (20 to 140 °F)
|
Max Thermal Shift ±0.8% Z±0.3%S
|
|
26 to 32 inHg
|
Barometric
|
<0.1%
|
±0.05%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 100°C (-40 to 220 °F)
|
Max Thermal Shift ±0.8% Z±0.3%S
|
|
26 to 32 inHg
|
Barometric
|
<0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-6 to 60 °C (20 to 140 °F)
|
Max Thermal Shift ±0.9% Z±0.6%S
|
High Accuracy oil filled Wet/Dray and Wet/Wet Differential Pressure Transducers
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 250 psi
|
Differential
|
< 0.1%
|
±0.08%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Differential
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-45 to 115 °C (-49 to 240 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Differential
|
< 0.1%
|
±0.08%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Differential
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-45 to 115 °C (-49 to 240 °F)
|
Wet/Wet Diff
|
|
0 to 1 psi
|
Differential
|
< 0.1%
|
±0.08%
|
Ratiometric mV/V
|
10 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Wet/Wet Diff
|
The PX880 series is FM and CSA approved for hazardous industrial locations and ideal for use with corrosive media and in hazardous environments. Available from 15 to 3,000 psi.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 300 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 5000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 15 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
The PX4200 series has titanium wetted parts for media compatibility and SOS construction is durable with excellent stability over a wide temperature range.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 300 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
DIN 43650 A
|
-40 to 80 °C (-40 to 176 °F)
|
Titanium Wetted Parts
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
DIN 43650 A
|
-40 to 80 °C (-40 to 176 °F)
|
Titanium Wetted Parts
|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
DIN 43650 A
|
-40 to 80 °C (-40 to 176 °F)
|
Titanium Wetted Parts
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
DIN 43650 A
|
-40 to 80 °C (-40 to 176 °F)
|
Titanium Wetted Parts
|
|
0 to 6,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
DIN 43650 A
|
-40 to 80 °C (-40 to 176 °F)
|
Titanium Wetted Parts
|
The PX653 series are well suited for use in clean rooms, HVAC systems, and laboratory fume hoods. They have a 4-20 mA or 1-5 V output in ranges from ± 0.05 to ± 50 inH2O.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
-2.5 to 2.5 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 3 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
The PX2300 series are ideal for measuring pressure drop across filters and/or in corrosive media, with a weatherproof, NEMA 4 enclosure and high ±0.25% accuracy.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 25 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 2 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 10 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
The PX190 series are compact, rugged, and cost effective with both current and voltage outputs to integrate with a variety of industrial and OEM applications.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 700 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
0 to 70 °C (32 to 158 °F)
|
|
0 to 75 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
0 to 70 °C (32 to 158 °F)
|
|
0 to 150 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
0 to 70 °C (32 to 158 °F)
|
|
0 to 200 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
0 to 70 °C (32 to 158 °F)
|
|
0 to 300 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
0 to 70 °C (32 to 158 °F)
|
The PX600 series are Omega's smallest transducers, but are still rugged and accurate for industrial environments. Available in ranges from 200 to 10,000 psi.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 2,000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 10000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
The PX509-IS series is FM approved, shock and vibration rated, with a ±0.08% accuracy, ideal for hazardous locations. Available in ranges from 10 inH2O to 5,000 psi.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 30 psi
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 15 psi
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 15 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
The PX01 series have a high ±0.09% accuracy and rugged, hermetically sealed housing that makes them suitable for harsh industrial and hydraulic environments.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 30,000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Voltage
|
0 to 10 Vdc
|
1/4"
|
High Pressure F-250-C
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-73 to 163 °C (-100 to 325 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Absolute
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
The PX3005-DIFF differential series are rangeable, with a backlit LCD display, ideal for monitoring pressures in process automation, hydraulic, and tank level applications.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
-1,000 to 1,000 inH2O
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-70 to 150 psi
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-25 to 25 inH2O
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-70 to 400 psi
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-160 to 160 inH2O
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
The PX3005 series are rangeable, with a backlit LCD display, ideal for monitoring pressures in process automation, hydraulic systems, pumps and tank level applications.
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
-15 to 5,000 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-1 to 1 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-3 to 3 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-5 to 5 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
0 to 15 psi
|
Absolute
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
Magnehelic® Differential Pressure Indicating Transmitter
Numéro de produit | Pressure Range | Pressure Type | Accuracy Class | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/ Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|
|
0 to 3 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-6.67 to 48.9°C (20 to 120°F)
|
|
0 to 0.50 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-6.67 to 48.9°C (20 to 120°F)
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-6.67 to 48.9°C (20 to 120°F)
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-6.67 to 48.9°C (20 to 120°F)
|
|
0 to 6 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-6.67 to 48.9°C (20 to 120°F)
|