text.skipToContent text.skipToNavigation

Thermocouples isolés avec des prises mini ou standard, avec ou sans rouleau embobinant, vendu en paquets de 5

Ready-Made Insulated Thermocouples with Kapton®, PFA, Glass Braid Insulation and Molded Connectors

C$160.00

Article# 5SRTC-TT-T-40-72

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$160.00
10-24 C$152.00
25-99 C$144.00
100-499 C$136.00
500-999 C$128.00
1000+ C$120.00

En stock

Délai de livraison (si pas en stock): 2 semaines

Ready-Made Insulated Thermocouples with Kapton®, PFA, Glass Braid Insulation and Molded Connectors 5SRTC-TT-T-40-72 5SRTC-TT-T-40-72
Ready-Made Insulated Thermocouples with Kapton, PFA, Glass Braid Insulation and Molded Connectors is rated 4.7 out of 5 by 20.
  • y_2021, m_4, d_11, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.14
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_20
  • loc_en_CA, sid_5SRTC-TT-T-40-72, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 1ms
  • REVIEWS, PRODUCT
  • Les prix indiqués sont pour les paquets de 5 thermocouples
  • Disponible pour les thermocouples de types J, K et T
  • Fils avec une tolérance classe 1
  • Isolation Kapton (temp. maxi 315°C )
  • Isolation soie de verre (temp. maxi 480°C )
  • Isolation PFA (temp. maxi 260°C )
  • Longueurs standard de 1 et 2 mètres
  • Connecteur sub-miniature moulé avec un réducteur de tension/rouleau embobinant intégré
  • Température de fonctionnement maximale du connecteur de 220°C
  • Lot de 5 pratique disponible en inventaire

Modifier les options

Voir tous les modèles

Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.

Category
Thermocouple Type
Process Temperature Range
Junction Type
Nominal Resistance
Accuracy
Number of Wires
Cable Insulation
Termination Connection Type
Cable Length
Color Code Standard
Wire Gauge
Pack Size
Additional Feature


Spécifications du produit

Description


Les thermocouples isolés sont fournis en lots de 5 et il y a 4 modèles différents en promotion sur cette page:

5SRTC avec une prise thermocouple miniature et une détente des contraintes pour le fil thermocouple.
5SC possède une prise thermocouple miniature avec un rouleau embobinant intégral pour stocker le fil thermocouple.
5LRTC avec une prise thermocouple miniature et une détente des contraintes pour le fil thermocouple.
5LSC possède une prise thermocouple miniature avec un rouleau embobinant intégral pour le fil thermocouple.

Tous les modèles sont disponibles avec des longueurs de fil de 1 ou 2 mètres et 3 types d'isolation de fil: Kapton et PFA offrent une bonne protéction contre l'humidité et l'abrasion et ont des températures de service nominales de 315°C et 260°C. L'isolation en soie de verre a une température de service nominale de 480°C. Les diamètres de fils disponibles sont de 0,08, 0,13, 0,25, 0,5 et 0,8 mm. Les diamètres plus petits ont un temps de réponse plus rapide tandis que les diamètres larges sont plus durables.


Des exemples de modèles courants sont indiqués dans le tableau "Pour commander". Plusieurs configurations sont immédiatement disponibles pour livraison. Vous pouvez consulter la notice technique (pdf) pour la liste de tous nos modèles disponibles ou vous pouvez également utiliser le "Tableau constructeur de référence" ci-dessous pour trouver le prix et la disponibilité du modèle désiré. 

Rated 4 out of 5 by from as advertised they are as advertised, and function the way they should
Date published: 2016-08-22
Rated 5 out of 5 by from Very useful thermocouples We have used dozens of these thermocouples over the last couple of years. Tjey are very reliable. Unfortunately, they are used in a destructive test and are usually used only once. But we keep coming back for more!
Date published: 2019-03-18
Rated 5 out of 5 by from Product Works as Expected The ready-made couples I received have quality cabling with stress relief and a quality housing. Never have had trouble with these thermocouples in the past.
Date published: 2021-03-04
Rated 4 out of 5 by from 5SC-TT-T-40-72 I recently purchased 100 TC's PN 5SC-TT-T-40-72. I noticed that ~1 in 50 are shorted inside the molded connector. When testing with a meter the TC reads ambient, when heat is applied to the junction it still reads ambient temperature. I suggest QA to add an additional check to the TC's prior to shipping to flag these TC's and remove them from stock.
Date published: 2021-02-11
Rated 4 out of 5 by from Omega Type-T Thin Thermocouple (30AWG) I like the product and have been using them for last 18 years. However sometimes the neck of male connector breaks and wires gets cut, although rarely. I propose two things - 1) please bring the price down and 2) please make some standalone piece or pack of 2 or 3 to accommodate customer's need and budget. Currently they come 5 in a box and priced accordingly.
Date published: 2021-01-27
Rated 5 out of 5 by from Completely Satisfied My applications aren’t exceptionally demanding. I needed replacements to use with an Omega meter after the old thermocouples’ insulation was chewed on by one of my cats. This product is exactly as described.
Date published: 2020-12-08
Rated 5 out of 5 by from Good as gold. No matter what you do. Thermocouples are prepared well for immediate work.
Date published: 2020-11-11
Rated 5 out of 5 by from Easy! Easy, easy, easy! Site is easy to navigate, easy to order, and product arrives quickly out of stock.
Date published: 2020-08-17
  • y_2021, m_4, d_11, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.14
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_20
  • loc_en_CA, sid_5SRTC-TT-T-40-72, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 1ms
  • REVIEWS, PRODUCT

What is the lowest Temperature that they read and what is the accuracy?

Asked by: Robyn
Hi, the lowest temperature depends on the Thermocouple type you choose and it depends upon the insulation material you choose as well; it’s a combining factor. If you need application information please contact our sales & application engineering team at temperature@omega.com. You can also reference this article for useful information. https://www.omega.com/en-us/resources/thermocouple-types
Answered by: Jane
Date published: 2019-05-01

HI, what is the accuracy of 5SRTC-TT-K-30-36 series! I check data sheet and do not see this value, tahnk you

Asked by: JIL2000
Thank you for your inquiry. The K-type standard limits of error would be "greater of 2.2°C or 0.75%" of range Hope this was helpful
Answered by: application engineer je
Date published: 2020-08-17

Is there special Fittings designed for this flat wire coupler to seal around the wire for oiled bearing assembly housings? Compression Fittings are only designed for Round Tubular couplers. Not Flat wire couplers. Please help!

Asked by: Mark S
Thank you for your inquiry. We only offer compression fittings for metal sheath probes. We do not offer any special fittings for this thermocouple series.
Answered by: Application Engineer JB
Date published: 2019-11-19

1. What is the difference between "mini male connector with spool cap" and "single spool, mini male connector with spool cap"? 2. It says the price as $70.36 for a pack of 5. So its 5 miniconnectors with 36" wire with each? Thank you.

Asked by: hmnola
Thank you for your inquiry. The descriptions both refer to the same product. The price that you see is for a 5 sensors total.
Answered by: Engineer CB
Date published: 2020-05-19

Do you have an epoxy available to coat the tips so they could be placed in a motor winding to read temperature?

Asked by: dcote
Thanks for connecting with Omega. Per your question, depending on the temperature, please review our OB-100/200 Series https://www.omega.com/en-us/sensors-and-sensing-equipment/sensing-accessories/adhesives-and-paste/p/OB-100-OB-200-OT-200
Answered by: Jane
Date published: 2019-06-26

Since these are sold in packs of five. If I purchase quantity 1 does that mean I will get one pack of 5?

Asked by: OJOnick
That is correct. QTY 1 = is one pack of 5. Please contact us at temp@omega.com if you have any further questions. Thanks!
Answered by: Jane
Date published: 2019-05-20

The product data sheet specifies "NIST Calibration Available" however I do not see how to specify that in the numbering scheme. For example I would like the 5SRTC-GG-K-30-108 with this option

Asked by: stevieboy
To get part number 5SRTC-GG-K-30-108 with NIST traceable certification you would have to use the Configure Now box on the 5SRTC page. This will let you build the part number step by step and one of the last steps is to answer with or without Calibration. If you hit YES then you'll get part number 5SRTC-GG-K-30-108-CAL-3. The link here will aid you in finding that builder. https://www.omega.com/en-us/search/?text=5srtc
Answered by: Engineer9
Date published: 2020-02-13

Would the exposed bead type thermocouple be suitable for use in Deionized water? If not, what are the concerns?

Asked by: Seth_Nickname
Thank you for your inquiry! Exposed thermocouples are not recommended for immersion/submersion in liquid because of the risk of a short. Deionized water may be less prone to this issue, but a probe is still the recommended option.
Answered by: Application Engineer JM
Date published: 2021-01-30
  • y_2021, m_4, d_11, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.14
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_8
  • loc_en_CA, sid_5SRTC-TT-T-40-72, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 1ms
  • QUESTIONS, PRODUCT

fr-CA
fr
Enregistrer la configuration